122 SOM-2080 6.1 1 Others 1005-001 Erroe ID Error Name, Description, Cause, and Remedy 4b2004 PCB Height Measurement The abnormality number of times of measured value was beyond a set point. ----- 4b2005 PCB Height Measu…

121
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b1801 Flux spread error
Component recognition is abnormal after flux spread.
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
4b1802 Flux spread error
Component recognition is abnormal after flux spread.
(1) Please confirm whether a flux spread device is installed definitely.
(2) Please confirm whether there is a residual quantity of flux.
(3) Please confirm whether a film thickness of a flux is formed normally.
4b1803 Flux spread error
The abnormality that there is no component after flux spread.(Sensor)
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
4b1901 Monoaxial zeroing is abnormal.
It detected abnormality during movement.
Please get rid of an abnormal factor
4b1902 Monoaxial zeroing is abnormal.
It is impossible of W2 axis zeroing.
Please perform W1 axis zeroing.
4b1a01 Process error
Failed in restoration of the Machine data.
Please execute restoration operation from NT again.
4b1a02 Process error
Failed in restoration of the Network data.
Please confirm the network setting.
4b1a03 Process error
Failed in data transfer.
Please reboot machine.
4b1a04 Process error
The machine operation has stopped after inside P.C.B.'s were transferred to the
out of the machine due to time-lag in the operation window process.
Reboot the machine. (Press the buttons of [Shutdown] →[Reboot] in the login tab
sheet.)
4b2001 PCB Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 PCB Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003 PCB Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----

122
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b2004 PCB Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 PCB Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006 PCB Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 PCB Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 PCB Height Measurement
Detected a curve more than permission values. (+ direction)
-----
4b2009 PCB Height Measurement
Detected a curve more than permission values. (- direction)
-----
4b200a PCB Height Measurement
Error of the result measured by a master jig (height)
Check if the master jig (height) has some dirt and foreign particles.
4b200b PCB Height Measurement
Failed in wearing height revision.
-----
4b200c PCB Height Measurement
An abnormal measurement was detected by the multipoint measurement.
Check the measurement position.
4b200d PCB Height Measurement
Recovery by the multipoint measurement failed because the measurement result
was insufficient.
Check the measurement position.
4b2011 PCB Height Measurement
Measurement time-out
-----
4b2081 PCB Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2082 PCB Height Measurement
Failed in wearing height revision.
-----
4b2083 PCB Height Measurement
Measurement time-out
-----

123
SOM-2080
6.11 Others
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
4b2084 PCB Height Measurement
The coordinate where the height measurement was impossible was appointed.
Please appoint a coordinate in a measurable range.
4b2101 SSC network abnormal
There is abnormal in SSC network.
Please confirm the cable of SSC network.
4b2102 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82 channel 1and amplifier.
(1) Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2103 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U82 channel 2and amplifier.
(1) Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2104 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U83 channel 1and amplifier.
(1) Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2105 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U83 channel 2 and amplifier.
(1) Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.
4b2106 SSC network abnormal
There is a problem with the connection between the position board MR-
MC10-U84 channel 1 and amplifier.
(1) Shut down the machine and check the connection between the position board
and amplifier.
(2) Check whether or not the multi-axis amplifier is damaged.
(3) Check whether or not the servo amplifiers are damaged.