SOM-2080-001_w.pdf - 第133页
130 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 4b2b02 Label Feeder The pick-up section in the label feeder (front) is not set correctly. Reset the pickup section in the label feeder correctly. 4b2c01 Er…

129
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
4b2901 Linear Scale Error
An error for the linear scale position occurred at the beam X-axis (rear) during
zeroing operation.
Please check the linear scale attaching position on the beam X-axis (rear).
4b2902 Linear Scale Error
An error for the linear scale position occurred at the beam X-axis (front) during
zeroing operation.
Please check the linear scale attaching position on the beam X-axis (front).
4b2903 Linear Scale Error
An error for the linear scale position occurred at the beam Y-axis (rear) during
zeroing operation.
(1) Check the linear scale on the beam Y-axis (rear).
(2) Check the linear scale attaching position on the Y1 and Y2.
(3) Check if the process of the linear scale origin mark on the Y1 and Y2 has an
error.
4b2904 Linear Scale Error
An error for the linear scale position occurred at the beam Y-axis (front) during
zeroing operation.
(1) Check the linear scale on the beam Y-axis (front).
(2) Check the linear scale attaching position on the Y1 and Y2.
(3) Check if the process of the linear scale origin mark on the Y1 and Y2 has an
error.
4b2905 Linear Scale Error
An error for the linear scale skip occurred at the beam Y-axis (rear) during zeroing
operation.
Please confirm if the linear scale on the beam Y-axis (rear) has flaws and soil.
4b2906 Linear Scale Error
An error for the linear scale skip occurred at the beam Y-axis (front) during
zeroing operation.
Please confirm if the linear scale on the beam Y-axis (front) has flaws and soil.
4b2907 Linear Scale Error
An error for the linear scale parallel offset deviation occurred at the beam Y-axis
(rear) during zeroing operation.
Please check the linear scale attaching condition on the beam Y-axis (rear).
4b2908 Linear Scale Error
An error for the linear scale parallel offset deviation occurred at the beam Y-axis
(front) during zeroing operation.
Please check the linear scale attaching condition on the beam Y-axis (front).
4b2a01 Splicing No Check Error
The seam reached the pick-up position as unregistered splicing. Please replenish
the component.
-----
4b2b01 Label Feeder
The pick-up section in the label feeder (rear) is not set correctly.
Reset the pickup section in the label feeder correctly.
6.11 Others
1005-001

130
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
4b2b02 Label Feeder
The pick-up section in the label feeder (front) is not set correctly.
Reset the pickup section in the label feeder correctly.
4b2c01 Error in communications between CPU
Failed in communications with the STG.#1 control CPU.
-----
4b2c02 Error in communications between CPU
Failed in communications with the STG.#2 control CPU.
-----
4b2c03 Error in communications between CPU
Failed in communications with the Recog CPU.
-----
4b2c04 Error in communications between CPU
Failed in communications with the Control CPU.
-----
4b2d01 Outside air blow
An error occurred in ON/OFF of the PEC Recog light.
-----
4b2d02 Outside air blow
An error occurred in the capture image of the Mark Recog.
-----
4b2d03 Outside air blow
A Mark Recog error occurred.
-----
4b2d04 Outside air blow
The operation of the outside air blow was not completed in time.
-----
4b2e01 Warning about Maintenance
The total number of the feeder shot exceeded the setting value. It is time to
perform the feeder maintenance.
-----
4b2f01 Splicing Error
A feeder joint section was detected as the splicing was unregistered.
Please do the mis-installing prevention check.
4b2f02 Splicing Error
Shortage of component was detected as the splicing was unregistered.
Please register the splicing and reload the component.
4b2f03 Splicing Error
The machine stopped for the mis-installing prevention check incompleteness end.
Please do the mis-installing prevention check.
6.11 Others
1005-001

131
SOM-2080
6.12 Pickup Error
1005-001
6.12 Pickup Error
Table 14
Erroe ID Error Name, Description, Cause, and Remedy
500101 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500102 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500201 Vacuum Sensor Error
-----
500301 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500302 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500401 Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500601 V.Bend Detection Error
-----
500701 Shortage of Component (Alternated Feeder)
-----
500a01 Auto Recovery Pause
Attach the new comp. And press [READY]. Then, press [START] button to re-
start.
-----
500a02 Auto Recovery Pause
Quick recovery stop
-----