SOM-2080-001_w.pdf - 第134页

131 SOM-2080 6.12 Pickup Error 1005-001 6.12 Pickup Error T able 14 Erroe ID Error Name, Description, Cause, and Remedy 500101 Comp. Missing (Sensor) There is a possibility that the picked comps. have fallen on the feede…

100%1 / 179
130
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
4b2b02 Label Feeder
The pick-up section in the label feeder (front) is not set correctly.
Reset the pickup section in the label feeder correctly.
4b2c01 Error in communications between CPU
Failed in communications with the STG.#1 control CPU.
-----
4b2c02 Error in communications between CPU
Failed in communications with the STG.#2 control CPU.
-----
4b2c03 Error in communications between CPU
Failed in communications with the Recog CPU.
-----
4b2c04 Error in communications between CPU
Failed in communications with the Control CPU.
-----
4b2d01 Outside air blow
An error occurred in ON/OFF of the PEC Recog light.
-----
4b2d02 Outside air blow
An error occurred in the capture image of the Mark Recog.
-----
4b2d03 Outside air blow
A Mark Recog error occurred.
-----
4b2d04 Outside air blow
The operation of the outside air blow was not completed in time.
-----
4b2e01 Warning about Maintenance
The total number of the feeder shot exceeded the setting value. It is time to
perform the feeder maintenance.
-----
4b2f01 Splicing Error
A feeder joint section was detected as the splicing was unregistered.
Please do the mis-installing prevention check.
4b2f02 Splicing Error
Shortage of component was detected as the splicing was unregistered.
Please register the splicing and reload the component.
4b2f03 Splicing Error
The machine stopped for the mis-installing prevention check incompleteness end.
Please do the mis-installing prevention check.
6.11 Others
1005-001
131
SOM-2080
6.12 Pickup Error
1005-001
6.12 Pickup Error
Table 14
Erroe ID Error Name, Description, Cause, and Remedy
500101 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500102 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500201 Vacuum Sensor Error
-----
500301 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500302 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500401 Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500601 V.Bend Detection Error
-----
500701 Shortage of Component (Alternated Feeder)
-----
500a01 Auto Recovery Pause
Attach the new comp. And press [READY]. Then, press [START] button to re-
start.
-----
500a02 Auto Recovery Pause
Quick recovery stop
-----
132
SOM-2080
6.12 Pickup Error
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
500c01 Comp. Vertical(Sensor)
Please confirm component thickness data (T,t) of the component library.
500d01 Comp. Missing (Sensor) After Chuck
-----
500e01 Comp. Missing (Sensor) Befor Mount
-----
500f01 Comp. Thickness(Sensor)
Please confirm component thickness data (T,t) of the component library.
501001 Comp. Missing (Sensor)
A pick-up error occurred in the pick-up operation.
After stage Ready Off, open the cover and remove the component on the feeder,
otherwise the component may hit to the head.
501101 Shortage of lot component
Shortage of lot component
Shortage of component occurred with a lot unit. Reload the component.
501201 Shortage of lot component
Please select "continue" or "Cancel".
-----
501301 Linear measure self check
Linear measure self check error occurred.
Check the linear measure function.
501401 Comp. Missing (Sensor and Camera)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.