SOM-2080-001_w.pdf - 第138页
135 SOM-2080 6.13 Automatic Operation Error 1005-001 Erroe ID Error Name, Description, Cause, and Remedy 510703 Auto Run Error Head Mis-Pick-up Detection Please do the comp. discard operation 510801 Auto Run Error Warm S…

134
SOM-2080
6.13 Automatic Operation Error
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
51010f Auto Run Error
Motor function set timeout
Please push the [emergency stop] button and execute Warm Start.
510110 Auto Run Error
Motor position data read error
Please push the [emergency stop] button and execute Warm Start.
510111 Auto Run Error
Please push the [emergency stop] button and execute Warm Start.
510201 Auto Run Error
Pattern program error
Please modify the pattern program.
510202 Auto Run Error
Component Library
Please modify the comp. Library.
510203 Auto Run Error
Operation Mode Error
-----
510204 Auto Run Error
The system setting data is abnormal.
-----
510301 Auto Run Error
JOB time-out during processing.
Please push the [emergency stop] button and return.
510302 Auto Run Error
JOB control Error
-----
510501 Auto Run Error
The recognition result response Error. (Before placement)
-----
510502 Auto Run Error
The recognition result response Error. (After placement)
-----
510601 Auto Run Error
Feeder Alarm
-----
510602 Auto Run Error
Feeder Error (Feed Timeout)
-----
510603 Auto Run Error
Pick-up Error
-----
510701 Auto Run Error
-----

135
SOM-2080
6.13 Automatic Operation Error
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
510703 Auto Run Error
Head Mis-Pick-up Detection
Please do the comp. discard operation
510801 Auto Run Error
Warm Start Error
Please position the P.C.B.
510901 Auto Run Error
Comp.Vertical
-----
510902 Auto Run Error
Comp.Missing(Sensor)
-----
510903 Auto Run Error
Comp.recog Error
-----
510904 Auto Run Error
Comp. Missing(Recog)
-----
510a01 Auto Run Error
Pocket recog Error
-----
510b01 Auto Run Error
Master bad mark detection is abnormal.
-----
510b02 Auto Run Error
Bad mark detection is abnormal.
-----
510c01 Auto Run Error
Component recognition is abnormal after flux spread.
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
510c02 Auto Run Error
The abnormality that there is no component after flux spread.(Sensor)
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
510d01 Auto Run Error
2D bar code reading error (Recog)
-----
510d02 Auto Run Error
2D bar code ID disagreement
-----
510e01 Auto Run Error
Displacement of fiducial mark occurred at the fiducial mark recognition (rear)
during auto operation.
Perform the beam offset teaching and check if the beam X/Y has deviation.

136
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
510e02 Auto Run Error
Displacement of fiducial mark occurred at the fiducial mark recognition (front)
during auto operation.
Perform the beam offset teaching and check if the beam X/Y has deviation.
510e03 Auto Run Error
A recognition error occurred at the fiducial mark recognition (rear) during auto
operation.
-----
510e04 Auto Run Error
A recognition error occurred at the fiducial mark recognition (front) during auto
operation.
-----
510e05 Auto Run Error
The Recog, operation of the fiducial mark (rear) was not completed within the
specified time.
-----
510e06 Auto Run Error
The Recog, operation of the fiducial mark (front) was not completed within the
specified time.
-----
510f01 Auto Run Error
It failed in the auto zeroing operation by pushing STOP PB or other stage's error.
Please start again.
510f02 Auto Run Error
It failed in the auto zeroing operation by pushing STOP PB or other stage's error.
Please start again.
510f03 Auto Run Error
It failed in the auto zeroing operation. (NL axis)
Please do the zeroing operation of stage 1 by the control menu.
510f04 Auto Run Error
It failed in the auto zeroing operation. (NL axis)
Please do the zeroing operation of stage 2 by the control menu.
510f05 Auto Run Error
It failed in the auto zeroing operation. (DD axis)
Please do the zeroing operation of stage 1 by the control menu.
510f06 Auto Run Error
It failed in the auto zeroing operation. (DD axis)
Please do the zeroing operation of stage 1 by the control menu.
510f07 Auto Run Error
Motor positioning error(HL axis)
When the fly was recognized, the positioning delay of the HL axis was detected.
Please exchange HL axes when happening frequently.
6.13 Automatic Operation Error
1005-001