SOM-2080-001_w.pdf - 第139页

136 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 510e02 Auto Run Error Di spl ac em ent of f idu ci al m ar k oc cu rre d a t th e fi du cia l ma rk rec og nit io n (f ro nt ) during auto operation. Perfo…

100%1 / 179
135
SOM-2080
6.13 Automatic Operation Error
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
510703 Auto Run Error
Head Mis-Pick-up Detection
Please do the comp. discard operation
510801 Auto Run Error
Warm Start Error
Please position the P.C.B.
510901 Auto Run Error
Comp.Vertical
-----
510902 Auto Run Error
Comp.Missing(Sensor)
-----
510903 Auto Run Error
Comp.recog Error
-----
510904 Auto Run Error
Comp. Missing(Recog)
-----
510a01 Auto Run Error
Pocket recog Error
-----
510b01 Auto Run Error
Master bad mark detection is abnormal.
-----
510b02 Auto Run Error
Bad mark detection is abnormal.
-----
510c01 Auto Run Error
Component recognition is abnormal after flux spread.
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
510c02 Auto Run Error
The abnormality that there is no component after flux spread.(Sensor)
Since the picked-up components may have fallen on the turntable of flux spread
equipment, please check it.
510d01 Auto Run Error
2D bar code reading error (Recog)
-----
510d02 Auto Run Error
2D bar code ID disagreement
-----
510e01 Auto Run Error
Displacement of fiducial mark occurred at the fiducial mark recognition (rear)
during auto operation.
Perform the beam offset teaching and check if the beam X/Y has deviation.
136
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
510e02 Auto Run Error
Displacement of fiducial mark occurred at the fiducial mark recognition (front)
during auto operation.
Perform the beam offset teaching and check if the beam X/Y has deviation.
510e03 Auto Run Error
A recognition error occurred at the fiducial mark recognition (rear) during auto
operation.
-----
510e04 Auto Run Error
A recognition error occurred at the fiducial mark recognition (front) during auto
operation.
-----
510e05 Auto Run Error
The Recog, operation of the fiducial mark (rear) was not completed within the
specified time.
-----
510e06 Auto Run Error
The Recog, operation of the ducial mark (front) was not completed within the
specified time.
-----
510f01 Auto Run Error
It failed in the auto zeroing operation by pushing STOP PB or other stage's error.
Please start again.
510f02 Auto Run Error
It failed in the auto zeroing operation by pushing STOP PB or other stage's error.
Please start again.
510f03 Auto Run Error
It failed in the auto zeroing operation. (NL axis)
Please do the zeroing operation of stage 1 by the control menu.
510f04 Auto Run Error
It failed in the auto zeroing operation. (NL axis)
Please do the zeroing operation of stage 2 by the control menu.
510f05 Auto Run Error
It failed in the auto zeroing operation. (DD axis)
Please do the zeroing operation of stage 1 by the control menu.
510f06 Auto Run Error
It failed in the auto zeroing operation. (DD axis)
Please do the zeroing operation of stage 1 by the control menu.
510f07 Auto Run Error
Motor positioning error(HL axis)
When the fly was recognized, the positioning delay of the HL axis was detected.
Please exchange HL axes when happening frequently.
6.13 Automatic Operation Error
1005-001
137
SOM-2080
6.14 Automatic Teaching
1005-001
6.14 Automatic Teaching
Table 16
Erroe ID Error Name, Description, Cause, and Remedy
600101 PCB recog camera & beam offset teach.
-----
600102 PCB recog camera & beam offset teach.
-----
600103 PCB recog camera & beam offset teach.
-----
600104 PCB recog camera & beam offset teach.
-----
600105 PCB recog camera & beam offset teach.
-----
600106 PCB recog camera & beam offset teach.
-----
600107 PCB recog camera & beam offset teach.
-----
600108 PCB recog camera & beam offset teach.
-----
600109 PCB recog camera & beam offset teach.
-----
600201 Comp. Recog Camera offset teach.
The glass Jig can not able to be recognized.
-----
600202 Comp. Recog Camera offset teach.
It entered in a specified frequency or less and it did not enter a permissible value.
-----
600203 Comp. Recog Camera offset teach.
-----
600301 Head Rotate Theta Axis offset
-----
600302 Head Rotate Theta Axis offset
-----