SOM-2080-001_w.pdf - 第149页

146 SOM-2080 6.15 T est 1005-001 6.15 T est T able 17 Erroe ID Error Name, Description, Cause, and Remedy 610101 Comp Recog Test The nozzle type data doesn't exist. ----- 610102 Comp Recog Test ----- 610103 Comp Rec…

100%1 / 179
145
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
602017 Auto. Teaching Mode in Auto.Opn
The offset value exceeded the tolerance at the beam offset teaching.(rear)
Open the "MAINT"/ "TEACHING" tab sheet and perform the "P.E..C. Recog.
Camera & Beam Offset".
602018 Auto. Teaching Mode in Auto.Opn
The offset value exceeded the tolerance at the beam offset teaching.(front)
Open the "MAINT"/ "TEACHING" tab sheet and perform the "P.E..C. Recog.
Camera & Beam Offset".
602019 Auto. Teaching Mode in Auto.Opn
The offset value exceeded the tolerance at the head center offset teaching.(rear)
Open the "MAINT"/ "TEACHING" tab sheet and perform the "Head Center Offset
Teaching".
60201a Auto. Teaching Mode in Auto.Opn
The offset value exceeded the tolerance at the head center offset teaching.(front)
Open the "MAINT"/ "TEACHING" tab sheet and perform the "Head Center Offset
Teaching".
60201b Auto. Teaching Mode in Auto.Opn
The offset value exceeded the tolerance at the basis mark position teaching.(rear)
Open the "MAINT"/ "TEACHING" tab sheet and perform the "Basis Mark Position
Teaching".
60201c Auto. Teaching Mode in Auto.Opn
The offset value exceeded the tolerance at the basis mark position teaching.(front)
Open the "MAINT"/ "TEACHING" tab sheet and perform the "Basis Mark Position
Teaching".
602101 Beam correct offset teach.
Mark can not be recognized on the glass Jig PCB.
Check the PCB position.
602102 Beam correct offset teach.
An error occurred on teaching operation.
Check the Rcg Communicatin or beam activity.
6.14 Automatic Teaching
1005-001
146
SOM-2080
6.15 Test
1005-001
6.15 Test
Table 17
Erroe ID Error Name, Description, Cause, and Remedy
610101 Comp Recog Test
The nozzle type data doesn't exist.
-----
610102 Comp Recog Test
-----
610103 Comp Recog Test
-----
610104 Comp Recog Test
-----
610105 Comp Recog Test
-----
610106 Comp Recog Test
-----
610107 Comp Recog Test
-----
610108 Comp Recog Test
-----
610109 Comp Recog Test
-----
610201 XY Beam Test
-----
610301 PEC Recog Test
-----
610401 PEC Recog Test
-----
610501 PEC Recog Test
-----
610601 Board height measurement adjustment
There is an abnormality in board height measurement adjustment.
-----
147
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
610602 Board height measurement adjustment
Measurement ranges exceed board size.
-----
610603 Board height measurement adjustment
There is the measurement point which exceed the board size.
-----
6.15 Test
1005-001