SOM-2080-001_w.pdf - 第162页

159 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 740f02 ACV check Splicing registration failed for the unused feeder. ----- 740f03 ACV check An error for the connection with the ACV server was found. Chec…

100%1 / 179
158
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
740b04 ACV check
Set "enable" for destination alternate feeder.[STG.#2]
-----
740b05 ACV check
The reel list check is not completed on STG.#1.
-----
740b06 ACV check
The reel list check is not completed on STG.#2.
-----
740c01 Component of ACV to be replenished information
Failed in registration of component to be replenished information (time-out).
Please confirm ACV server connection, and start producing.
-----
740c02 Component of ACV to be replenished information
Failed in registration of component to be replenished information (Data error 1).
Please confirm server connection or re-registration of component.
-----
740c03 Component of ACV to be replenished information
Failed in registration of component to be replenished information (Data error 2).
Please confirm server connection or re-registration of component.
-----
740d01 Server function
Failed in the access to the component information.
-----
740d02 Server function
Failed in the information output to the data base.
-----
740d03 Server function
failed in the transmission of Stored procedure function.
-----
740d04 Server function
Failed in the registration of the component information,
-----
740d05 Server function
Failed in the registration of Feedef/Component set data,
-----
740e01 ACV server
Failed in the registration of the component information,
-----
740e02 ACV server
Failed in the registration of Feedef/Component set data,
-----
740f01 ACV check
Splicing registration failed.
-----
6.18 ACV
1005-001
159
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
740f02 ACV check
Splicing registration failed for the unused feeder.
-----
740f03 ACV check
An error for the connection with the ACV server was found. Check the ACV server
and after check, try to connect it again at the [MAINT] - [UNIT ADJ] - [ACV ADJ]
tab sheet.
-----
6.18 ACV
1005-001
160
SOM-2080
6.19 Machine Information
1005-001
6.19 Machine Information
Table 21
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
800101 Auto Noz. Bypass Started
Nozzle down error(L)
800102 Auto Noz. Bypass Started
Nozzle down error(H)
800103 Auto Noz. Bypass Started
Handling err-cont:
800104 Auto Noz. Bypass Started
Decreasing of comp.handling rate
800105 Auto Noz. Bypass Started
Selected nozzle position error
800106 Auto Noz. Bypass Started
Nozzle Posture Detection
800201 Auto Head Bypass Started
Communication error.
800202 Auto Head Bypass Started
Head origin error.
800203 Auto Head Bypass Started
Overtime head origin error. Set ct:3(fixed value)
800204 Auto Head Bypass Started
Unselected nozzle drop. Set ct:2(fixed value)
800205 Auto Head Bypass Started
CAM position.
800206 Auto Head Bypass Started
Origin Return Action.
800207 Auto Head Bypass Started
Motor Out of Control
800208 Auto Head Bypass Started
Current OverLoad.
800209 Auto Head Bypass Started
Motor not connected.
800210 Auto Head Bypass Started
Solenoid not connected.
800211 Auto Head Bypass Started
Power line warning.
800212 Auto Head Bypass Started
Power line error.
800213 Auto Head Bypass Started
Driver temperature warning.
800214 Auto Head Bypass Started
Driver temperature error.