SOM-2080-001_w.pdf - 第171页

168 SOM-2080 Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 801a06 Warning Operation The status for the starting protection changed to ON. 801b01…

100%1 / 179
167
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801707 Teach Nozzle Bypass
Nozzle Drop
801708 Teach Nozzle Bypass
Dummy Nozzle.
801709 Teach Nozzle Bypass
Manual Bypass.
80170a Teach Nozzle Bypass
Nozzle Change Error.(Cam lock action)
80170b Teach Nozzle Bypass
Nozzle Change Error.(Cam Free action)
80170c Teach Nozzle Bypass
Cam Origin Error.
80170d Teach Nozzle Bypass
Nozzle Teach Error.
80170e Teach Nozzle Bypass
Nozzle Posture Detection
801801 Teach Head Bypass
Communication Error.
801802 Teach Head Bypass
Head Origin.
801803 Teach Head Bypass
Overtime Head Origin Return.
801804 Teach Head Bypass
Unselected Nozzle Drop.
801805 Teach Head Bypass
Dummy Nozzle.
801806 Teach Head Bypass
Manual Bypass.
801807 Teach Head Bypass
Alarm Error.
801901 Nozzle Adjustment
Nozzle up&down action is not available.
801902 Nozzle Adjustment
Communication error.
801a01 Warning Operation
Product started by RUN MODE "PASS"Operation.
801a02 Warning Operation
The PCB before component placing was conveyed from X/Y table.
801a03 Warning Operation
The PCB in the middle of component placing was conveyed from X/Y table.
801a04 Warning Operation
The feeder ready button was turned on in start protection mode.
801a05 Warning Operation
Cannot alternate by external start protection.
6.19 Machine Information
1005-001
168
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801a06 Warning Operation
The status for the starting protection changed to ON.
801b01 Lightning Surge Warning
Lightning Surge Protector works; Q204.
801b02 Lightning Surge Warning
Lightning Surge Protector works; Q204. Running continue.
801c01 Information
This placement step was detected outside of the possible range. This step is auto
skip running.
801c02 Information
Feeder carriage has been paused to avoid clash with missing component. Please
collect component before operating the feeder carriage.
801c03 Information
Data was changed during machine worked. The changed data is not reflected in
operation until it stops or interrupts operation.
801c04 Information
PCB Origin Position data is not right. Please correct a PCB Origin Position on a
"Prod Chng(Origin Pos)" screen.
801c05 Information
Warm start mode was canceled.
801c06 Information
The machine stopped by the automatic stop function.
801c07 Information
Warm start mode was canceled. Please remove the unaccomplished PCB
801c08 Information
Started with abnormal feeder B offset data. Feeder B offset X and Y for 8mm tape
width, 2mm feed pitch component should be less than +/- 1.0mm.
801c09 Information
It started with the data out of the setting range contained in the placement level
data of component supply changed data. On edit screen, the place level of square
shape below 3216 should be set up less than +0.5mm. When the place level
exceeding 0.5mm is required, please input H data of placement data (PP data).
801c0a Information
The number of times of flux reload reached the preset number of times. Please
confirm flux in a syringe is not insufficient.
801c0b Information
The PCB product operation was cancelled on the way of the placement operation
by shortage of lot component. Open the safety cover and remove the PCB
directly.
801c0c Information
The Warm Start Mode on the stage1was canceled.
801c0d Information
The Warm Start Mode on the stage2 was canceled.
6.19 Machine Information
1005-001
169
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801c0e Information
The machine operation was stopped by a function of the P.C.B. counter stop
mode.
801c0f Information
Time-lag was detected in the process of the operation window. The machine
operation will be stopped after inside P.C.B.'s are transferred to the out of the
machine. Please reboot the machine after stop of the machine operation.
801d01 Semi-auto(continue) start mode auto change
Production operation was interrupted for the state where PCB before component
are placed exists on XY table.
801e01 Placement Level Data
Calculated data out of range. Please check library data and pattern program data.
801f01 Warm start mode auto change
Operation was canceled for the state where the PCB in the middle of component
placing is on X/Y table.
802001 Alarm for Splicing
The feeder is running short of the component to feed. Please prepare for Splicing,
and remove the cover tape from the storage section.
802101 Feeder Maintenance Warning
The total number of feeder's shots reached a previous notice setting number.
802102 Feeder Maintenance Warning
The feeder adsorption rate decreased and exceeded the previous notice setting
number.
802201 ACV Information
Changing the feeder alternate condition to 'Disable' for ACV found empty feeder.
802202 ACV Information
Changing the feeder alternate condition to 'Disable' for ACV found missing feeder.
802203 ACV Information
It faild in the Conv.Table and it failed in setting.
802301 Splicing No Check Alarm
The seam passed the detection sensor as unregistered splicing. Please register
the splicing.
803001 FAN Stop Warning
The ceiling cooling fan stopped.
803002 FAN Stop Warning
The lower mount (left fornt) cooling fan stopped.(M105)
803003 FAN Stop Warning
The lower mount (left rear) cooling fan stopped.(M106)
803004 FAN Stop Warning
The upper mount (left front) cooling fan stopped.(M107)
803005 FAN Stop Warning
The upper mount (left rear) cooling fan stopped.(M108)
803006 FAN Stop Warning
The lower mount side (left front) cooling fan stopped.(M109)
6.19 Machine Information
1005-001