SOM-2080-001_w.pdf - 第173页
170 SOM-2080 Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 803007 FAN Stop Warning The lower mount side (left rear) cooling fan stopped.(M110) 8…

169
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801c0e Information
The machine operation was stopped by a function of the P.C.B. counter stop
mode.
801c0f Information
Time-lag was detected in the process of the operation window. The machine
operation will be stopped after inside P.C.B.'s are transferred to the out of the
machine. Please reboot the machine after stop of the machine operation.
801d01 Semi-auto(continue) start mode auto change
Production operation was interrupted for the state where PCB before component
are placed exists on XY table.
801e01 Placement Level Data
Calculated data out of range. Please check library data and pattern program data.
801f01 Warm start mode auto change
Operation was canceled for the state where the PCB in the middle of component
placing is on X/Y table.
802001 Alarm for Splicing
The feeder is running short of the component to feed. Please prepare for Splicing,
and remove the cover tape from the storage section.
802101 Feeder Maintenance Warning
The total number of feeder's shots reached a previous notice setting number.
802102 Feeder Maintenance Warning
The feeder adsorption rate decreased and exceeded the previous notice setting
number.
802201 ACV Information
Changing the feeder alternate condition to 'Disable' for ACV found empty feeder.
802202 ACV Information
Changing the feeder alternate condition to 'Disable' for ACV found missing feeder.
802203 ACV Information
It faild in the Conv.Table and it failed in setting.
802301 Splicing No Check Alarm
The seam passed the detection sensor as unregistered splicing. Please register
the splicing.
803001 FAN Stop Warning
The ceiling cooling fan stopped.
803002 FAN Stop Warning
The lower mount (left fornt) cooling fan stopped.(M105)
803003 FAN Stop Warning
The lower mount (left rear) cooling fan stopped.(M106)
803004 FAN Stop Warning
The upper mount (left front) cooling fan stopped.(M107)
803005 FAN Stop Warning
The upper mount (left rear) cooling fan stopped.(M108)
803006 FAN Stop Warning
The lower mount side (left front) cooling fan stopped.(M109)
6.19 Machine Information
1005-001

170
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
803007 FAN Stop Warning
The lower mount side (left rear) cooling fan stopped.(M110)
803008 FAN Stop Warning
The CPU2 control box (left) cooling fan stopped.(M111)
803009 FAN Stop Warning
Fan stop detection satellite [STLT_FAN_MON] It does not answer. A fan stop is
normally undetectable.
80300a FAN Stop Warning
The conveyor multi-axis amplifier (left) cooling fan stopped.(M122)
80300b FAN Stop Warning
The lower mount side (right front) cooling fan stopped.(M116)
80300c FAN Stop Warning
The lower mount side (right rear) cooling fan stopped.(M117)
80300d FAN Stop Warning
The recognition BOX cooling fan stopped.(M118)
80300e FAN Stop Warning
The electrical system box power supply cooling fan (left) stopped.(M119)
80300f FAN Stop Warning
The electrical system box power supply cooling fan (right) stopped.(M120)
803010 FAN Stop Warning
The ceiling (left front) cooling fan stopped.(M102)
803011 FAN Stop Warning
The ceiling (left rear) cooling fan stopped.(M101)
803012 FAN Stop Warning
The ceiling (right front) cooling fan stopped.(M104)
803013 FAN Stop Warning
The ceiling (right rear) cooling fan stopped.(M103)
803014 FAN Stop Warning
The lower mount (right fornt) cooling fan stopped.(M112)
803015 FAN Stop Warning
The lower mount (right rear) cooling fan stopped.(M113)
803016 FAN Stop Warning
The upper mount (right front) cooling fan stopped.(M114)
803017 FAN Stop Warning
The upper mount (right rear) cooling fan stopped.(M115)
803018 FAN Stop Warning
The CPU2 control box (right) cooling fan stopped.(M118)
803019 FAN Stop Warning
The conveyor multi-axis amplifier (right) cooling fan stopped.(M124)
80301a FAN Stop Warning
The ceiling (rear) cooling fan stopped.(M101)
80301b FAN Stop Warning
The ceiling (front) cooling fan stopped.(M102)
6.19 Machine Information
1005-001

171
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
80301c FAN Stop Warning
The electrical system box power supply cooling fan (left) stopped.(M121)
80301d FAN Stop Warning
The electrical system box power supply cooling fan (right) stopped.(M123)
80301e FAN Stop Warning
The conveyor multi-axis amplifier cooling fan stopped.(M112)
80301f FAN Stop Warning
The cooling fan stopped on the left-back side of the electrical box. (M177)
803020 FAN Stop Warning
The cooling fan stopped on the right-back side of the electrical box. (M178)
803021 FAN Stop Warning
The cooling fan stopped on the conveyor multi-axis amplifier (left). (M122)
803022 FAN Stop Warning
The cooling fan stopped on the conveyor multi-axis amplifier (right). (M124)
803023 FAN Stop Warning
The cooling fan stopped on the DC power source G2 (left). (M171)
803024 FAN Stop Warning
The cooling fan stopped on the DC power source G2 (right). (M173)
803025 FAN Stop Warning
The cooling fan stopped on the DC power source G4 (left). (M172)
803026 FAN Stop Warning
The cooling fan stopped on the DC power source G4 (right). (M174)
803027 FAN Stop Warning
The cooling fan stopped on the right electrical box. (M175)
804001 Warning of Specified Test Mode
"Enable" is set for the [Backup Base Axis Aging] in the Test Mode. Be sure to
check that there is no backup pin and jig under the chute because the backup
base will move up and down.
805001 Auto. Teaching Mode in Auto.Opn
The automatic teaching was performed during Auto. Opn. (Stage1)
805002 Auto. Teaching Mode in Auto.Opn
The automatic teaching was performed during Auto. Opn. (Stage2)
809001 Internal Exception Notice
CPU2 Vector 0 exception has been disregarded.
809002 Internal Exception Notice
CPU2 spurious exception has been disregarded.
809003 Internal Exception Notice
CPU2 undefined exception has been disregarded.
809004 Internal Exception Notice
CPU3 undefined exception has been disregarded.
809005 Internal Exception Notice
EB005 SYSFAIL exception has been disregarded.
809101 Cutting tape Preliminary announcement
Please cut a tape in a predetermined position.
6.19 Machine Information
1005-001