172 SOM-2080 Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 809201 Library tape width check The tape width in library and the feeder are not in a…

171
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
80301c FAN Stop Warning
The electrical system box power supply cooling fan (left) stopped.(M121)
80301d FAN Stop Warning
The electrical system box power supply cooling fan (right) stopped.(M123)
80301e FAN Stop Warning
The conveyor multi-axis amplifier cooling fan stopped.(M112)
80301f FAN Stop Warning
The cooling fan stopped on the left-back side of the electrical box. (M177)
803020 FAN Stop Warning
The cooling fan stopped on the right-back side of the electrical box. (M178)
803021 FAN Stop Warning
The cooling fan stopped on the conveyor multi-axis amplifier (left). (M122)
803022 FAN Stop Warning
The cooling fan stopped on the conveyor multi-axis amplifier (right). (M124)
803023 FAN Stop Warning
The cooling fan stopped on the DC power source G2 (left). (M171)
803024 FAN Stop Warning
The cooling fan stopped on the DC power source G2 (right). (M173)
803025 FAN Stop Warning
The cooling fan stopped on the DC power source G4 (left). (M172)
803026 FAN Stop Warning
The cooling fan stopped on the DC power source G4 (right). (M174)
803027 FAN Stop Warning
The cooling fan stopped on the right electrical box. (M175)
804001 Warning of Specified Test Mode
"Enable" is set for the [Backup Base Axis Aging] in the Test Mode. Be sure to
check that there is no backup pin and jig under the chute because the backup
base will move up and down.
805001 Auto. Teaching Mode in Auto.Opn
The automatic teaching was performed during Auto. Opn. (Stage1)
805002 Auto. Teaching Mode in Auto.Opn
The automatic teaching was performed during Auto. Opn. (Stage2)
809001 Internal Exception Notice
CPU2 Vector 0 exception has been disregarded.
809002 Internal Exception Notice
CPU2 spurious exception has been disregarded.
809003 Internal Exception Notice
CPU2 undefined exception has been disregarded.
809004 Internal Exception Notice
CPU3 undefined exception has been disregarded.
809005 Internal Exception Notice
EB005 SYSFAIL exception has been disregarded.
809101 Cutting tape Preliminary announcement
Please cut a tape in a predetermined position.
6.19 Machine Information
1005-001

172
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
809201 Library tape width check
The tape width in library and the feeder are not in agreement. Please check the
library and feeder.
809301 Conveyor upper cover opening and closing
Input conveyor upper cover opened.
809302 Conveyor upper cover opening and closing
Input conveyor upper cover closed.
809303 Conveyor upper cover opening and closing
Output conveyor upper cover opened.
809304 Conveyor upper cover opening and closing
Output conveyor upper cover closed.
809305 Conveyor upper cover opening and closing
Input machine conveyor upper cover opened.
809306 Conveyor upper cover opening and closing
Input machine conveyor upper cover closed.
809307 Conveyor upper cover opening and closing
Output machine conveyor upper cover opened.
809308 Conveyor upper cover opening and closing
Output machine conveyor upper cover closed.
809401 PCB existence
The PCB which carried out manual bypass to the input conveyor was detected.
809402 PCB existence
The PCB on a output conveyor was removed.
809501 Conveyor forbidden operation signal detected
The input conveyor changed into the forbidden state of operation.
809502 Conveyor forbidden operation signal detected
The forbidden operation state of the input conveyor of was canceled.
809503 Conveyor forbidden operation signal detected
The output conveyor changed into the forbidden state of operation.
809504 Conveyor forbidden operation signal detected
The forbidden operation state of the output conveyor of was canceled.
809601 Flux automatic reload movement.
The flux automatic reload is running.
809701 PCB Stopper
"Disable"was set for the PCB stopper in the system data.
809702 PCB Stopper
"Disable"was set for the reversal PCB stopper in the system data.
809703 PCB Stopper
"Disable"was set for the PCB stopper in the pattern program data.
809704 PCB Stopper
"Disable"was set for the reversal PCB stopper in the pattern program data.
809705 PCB Stopper
"Disable"was set for the PCB stopper in the system data/ pattern program data.
6.19 Machine Information
1005-001

173
SOM-2080
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
809706 PCB Stopper
"Disable"was set for the reversal PCB stopper in the system data/ pattern
program data.
809711 PCB Stopper
The rise operating time of the P.C.B. stopper is too fast. Please adjust it so that
an operating time becomes 90-190ms.
809712 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too fast. Please adjust it
so that an operating time becomes 90-190ms.
809713 PCB Stopper
The rise operating time of the P.C.B. stopper is too slow. Please adjust it so that
an operating time becomes 90-190ms.
809714 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too slow. Please adjust it
so that an operating time becomes 90-190ms.
809715 PCB Stopper
The drop operating time of the P.C.B. stopper is too fast. Please adjust it so that
an operating time becomes 190-290ms.
809716 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too fast. Please adjust it
so that an operating time becomes 190-290ms.
809717 PCB Stopper
The drop operating time of the P.C.B. stopper is too slow. Please adjust it so that
an operating time becomes 190-290ms.
809718 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too slow. Please adjust
it so that an operating time becomes 190-290ms.
809801 Feeder alternate condition is disable.
Original and alternated feeders have had pick-up errors and they are under
disabled status. After finding the cause of pick-up errors, go to the main menu,
then [OPERATION], [Altn Mode], select feeder lane number, enable feeder(s)
to clear disabled status, go back to the main menu and press the start button to
resume.
809901 Flux residual quantity detection sensor
It reached the predetermined number of times of a dip, but automatic reload
movement was not carried out. Please confirms quantity of a flux on a disk, and
confirm sensitivity of a sensor.
809902 Flux residual quantity detection sensor
Automatic reload movement was surplus carried out for the predetermined
number of times of a dip. Please confirms quantity of a flux on a disk, and confirm
sensitivity of a sensor.
6.19 Machine Information
1005-001