18 SOM-2080 1005-001 6.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 420601 PCB detectada no conveyor de saída Erro de sinal de SMEMA na saída ----- 420602 PCB detectada no conveyor de saída A PCB locali…

17
SOM-2080
1005-001
6.3 Conveyor
6.3 Conveyor
Table 5
Erroe ID Error Name, Description, Cause, and Remedy
420101 Tempo excedido no buffer do conveyor de entrada
A PCB não foi transportada para o buffer de entrada
-----
420102 Tempo excedido no buffer do conveyor de entrada
O conveyor do buffer de entrada não pode transportar a PCB corretamente
-----
420201 Tempo excedido no conveyor de entrada
O conveyor de entrada não pode transportar a PCB corretamente
-----
420202 Tempo excedido no conveyor de entrada
A PCB vinda do conveyor de entrada não foi transportada corretamente
-----
420203 Tempo excedido no conveyor de entrada
A PCB localizada na mesa não pode ser transportada
-----
420301 Tempo excedido no conveyor de saída
A PCB não foi transferida no conveyor de saída
-----
420302 Tempo excedido no conveyor de saída
A PCB que está no conveyor de saída não pode ser transferida
-----
420401 PCB detectada no buffer do conveyor de entrada
Erro de sinal de SMEMA na entrada
-----
420402 PCB detectada no buffer do conveyor de entrada
Existem PCB's na entrada e saída do conveyor de entrada
-----
420403 PCB detectada no buffer do conveyor de entrada
Foi detectada uma PCB no conveyor de entrada
-----
420404 PCB detectada no buffer do conveyor de entrada
Foi detectada uma PCB no conveyor de entrada
-----
420501 PCB detectada no conveyor de entrada
O sensor está em posição errada
-----
420502 PCB detectada no conveyor de entrada
Existem PCB's na entrada e saída do conveyor de entrada
-----
420503 PCB detectada no conveyor de entrada
A PCB localizada no conveyor de entrada não pode ser transferida
-----

18
SOM-2080
1005-001
6.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
420601 PCB detectada no conveyor de saída
Erro de sinal de SMEMA na saída
-----
420602 PCB detectada no conveyor de saída
A PCB localizada no conveyor de saída náo pode ser transferida
-----
420701 PCB Stopper
O PCB Stopper não atuou
Por favor, verifique se o Stopper est
á funcionando corretamente
420702 PCB Stopper
O PCB Stopper não atuou
Por favor, verifique se o Stopper est
á funcionando corretamente
420703 PCB Stopper
O PCB Stopper não atuou
Por favor, verifique se o Stopper est
á funcionando corretamente
420704 PCB Stopper
O PCB Stopper não atuou
Por favor, verifique se o Stopper est
á funcionando corretamente
420705 PCB Stopper
O PCB Stopper não atuou
Por favor, verifique se o Stopper est
á funcionando corretamente
420706 PCB Stopper
O PCB Stopper não atuou
Por favor, verifique se o Stopper est
á funcionando corretamente
420711 PCB Stopper
The rise operating time of the P.C.B. stopper is too fast.
Please adjust it so that an operating time becomes 90-190ms.
420712 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too fast.
Please adjust it so that an operating time becomes 90-190ms.
420713 PCB Stopper
The rise operating time of the P.C.B. stopper is too slow.
Please adjust it so that an operating time becomes 90-190ms.
420714 PCB Stopper
The rise operating time of the reversal P.C.B. stopper is too slow.
Please adjust it so that an operating time becomes 90-190ms.
420715 PCB Stopper
The drop operating time of the P.C.B. stopper is too fast.
Please adjust it so that an operating time becomes 190-290ms.
420716 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too fast.
Please adjust it so that an operating time becomes 190-290ms.
420717 PCB Stopper
The drop operating time of the P.C.B. stopper is too slow.
Please adjust it so that an operating time becomes 190-290ms.

19
SOM-2080
1005-001
6.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
420718 PCB Stopper
The drop operating time of the reversal P.C.B. stopper is too slow.
Please adjust it so that an operating time becomes 190-290ms.
420801 Manual transfer error
Ocorreu um erro quando a operação foi iniciada
-----
420802 Manual transfer error
Erro detectado durante operação
-----
420803 Manual transfer error
O tempo para finalização da operação foi excedido
-----
420804 Manual transfer error
Falha de leitura da PCB entre os estágios
-----
420901 Transfer Error (Others)
Por favor verifique a PCB em cada conveyor
-----
420902 Transfer Error (Others)
Tempo de comunicação excedido durante o processo de inicialização do transfer
Reiniciar a operação
420a01 Chute Clamp
Erro de atuação do clamp (estágio 1) antes da operação dos eixos NB-W
Execute a operação novamente, se o problema persistir, verifique o
funcionamento do sensor de pressão do clamp
420a02 Chute Clamp
Erro de atuação do clamp (estágio 2) antes da operação dos eixos NB-W
Execute a operação novamente, se o problema persistir, verifique o
funcionamento do sensor de pressão do clamp
420a03 Chute Clamp
Erro de atuação do clamp antes da operação dos eixos NB-W
Execute a operação novamente, se o problema persistir, verifique o
funcionamento do sensor de pressão do clamp
420a04 Chute Clamp
Falha ao receber a informação do clamp entre os estágios antes da operação
dos eixos NB-W
Execute a operação novamente
421101 Input Buffer Cnvr Overtime
A PCB não foi transportada para o buffer de entrada
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
421102 Input Buffer Cnvr Overtime
O conveyor não finalizou a operação no tempo certo
Por favor, verifique posicionamento da PCB no conveyor e continue a operação