6.3 Conveyor
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
423307 Input Cnvr Error
The PCB was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
423308 Input Cnvr Error
The process of inside signal between conveyors failed.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
423309 Input Cnvr Error
Speed reduction was not performed during PCB transfer operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424101 Cnvr Positoining2 Overtime
The PCB transport (carry in) from input cnvr did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424102 Cnvr Positoining2 Overtime
The PCB transport (exhaust) to output cnvr did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424103 Cnvr Positoining2 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
424104 Cnvr Positoining2 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
424106 Cnvr Positoining2 Overtime
The positioning change operation did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424107 Input Cnvr Error
The reversal positioning operation did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424108 Input Cnvr Error
The PCB transfer operation could not be completed in time.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424109 Input Cnvr Error
The process of the Bad Mark transfer was not completed within regular hours.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424201 Cnvr Positioning2 PCB Detection
PCB's were at inlet and outlet of cnvr.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424202 Cnvr Positioning2 PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able
to be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação

28
SOM-2080
6.3 Conveyor
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
424203 Cnvr Positioning2 PCB Detection
No PCB on the cnvr After positioning released, PCB could not be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424204 Cnvr Positioning2 PCB Detection
The conveyer entrance sensor detected PCB
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424205 Cnvr Positioning2 PCB Detection
The PCB that has not been positioned exists.
Please position the P.C.B.
424206 Cnvr Positioning2 PCB Detection
An unsuitable detected state of the sensor is being kept.
Please remove the factor that the sensor detects. (The operation delay of the dirt
of the sensor or Z clamping descent is thought. )
424207 Cnvr Positioning2 PCB Detection
The PCB was unsuitable detected at the time of a carrying-in operation start.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
424208 Cnvr Positioning2 PCB Detection
The PCB was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424301 Cnvr Positioning2 Error
The carrying in operation was not able to begin.
-----
424302 Cnvr Positioning2 Error
The error was detected while carrying in was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424303 Cnvr Positioning2 Error
The exhaust operation was not able to begin.
-----
424304 Cnvr Positioning2 Error
The error was detected while exhaust was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424305 Cnvr Positioning2 Error
The error was detected while the backup base was rising.
-----
424306 Cnvr Positioning2 Error
The error was detected while the backup base was descending.
-----
424307 Cnvr Positioning2 Error
Rise operation of a PCB stopper is not completed.
Please check a stopper.

29
SOM-2080
6.3 Conveyor
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
424308 Cnvr Positioning2 Error
Downward operation of a PCB stopper is not completed.
Please check a stopper.
424309 Cnvr Positioning2 Error
The positioning change operation was not able to begin.
-----
424310 Cnvr Positioning2 Error
The error was detected while the positioning change was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424311 Cnvr Positioning2 Error
The reversal positioning operation was not able to begin.
-----
424312 Cnvr Positioning2 Error
The error was detected while the reversal positioning was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424313 Cnvr Positioning2 Error
Pick-up of a PCB went wrong.
Please check the existence of P.C.B or whether the support Jig has reached the
P.C.B.
424314 Cnvr Positioning2 Error
The pick-up OFF of a PCB went wrong.
-----
424315 Cnvr Positioning2 Error
Slowdown operation was not carried out at the time of carrying-in operation.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
424316 Cnvr Positioning2 Error
Rise operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
424317 Cnvr Positioning2 Error
Downward operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
424318 Cnvr Positioning2 Error
The PCB was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
424319 Cnvr Positioning2 Error
The process of inside signal between conveyors failed.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424320 Cnvr Positioning2 Error
The PCB transfer operation could not start.
-----