30 SOM-2080 6.3 Conveyor 1005-001 Erroe ID Error Name, Description, Cause, and Remedy 424321 Cnvr Positioning2 Error An error was detected in transferring the PCB. Por favor, verifique posicionamento da PCB no conveyor e …

29
SOM-2080
6.3 Conveyor
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
424308 Cnvr Positioning2 Error
Downward operation of a PCB stopper is not completed.
Please check a stopper.
424309 Cnvr Positioning2 Error
The positioning change operation was not able to begin.
-----
424310 Cnvr Positioning2 Error
The error was detected while the positioning change was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424311 Cnvr Positioning2 Error
The reversal positioning operation was not able to begin.
-----
424312 Cnvr Positioning2 Error
The error was detected while the reversal positioning was operating.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424313 Cnvr Positioning2 Error
Pick-up of a PCB went wrong.
Please check the existence of P.C.B or whether the support Jig has reached the
P.C.B.
424314 Cnvr Positioning2 Error
The pick-up OFF of a PCB went wrong.
-----
424315 Cnvr Positioning2 Error
Slowdown operation was not carried out at the time of carrying-in operation.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
424316 Cnvr Positioning2 Error
Rise operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
424317 Cnvr Positioning2 Error
Downward operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
424318 Cnvr Positioning2 Error
The PCB was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
424319 Cnvr Positioning2 Error
The process of inside signal between conveyors failed.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424320 Cnvr Positioning2 Error
The PCB transfer operation could not start.
-----

30
SOM-2080
6.3 Conveyor
1005-001
Erroe ID Error Name, Description, Cause, and Remedy
424321 Cnvr Positioning2 Error
An error was detected in transferring the PCB.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
424322 Cnvr Positioning2 Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly
424323 Cnvr Positioning2 Error
A servo error was found in the movement that the backup base was rising. The
backup jig and pins may be left under the transfer rail.
Cancel the error and perform zeroing operation after that, open the cover to
remove the left backup jig and pins under the transfer rail. Perform the setup
operation again to set the backup jig and the pins to the proper positions.
424324 Cnvr Positioning2 Error
Support pins /Jig were detected before the backup base starts to rise.
Remove the support pins / jig from the backup base. If the removong operation is
difficult, perform the function to move the support pin changing position.
424325 Cnvr Positioning2 Error
Error data was transferred in the process of the bad mark transfer.
Please check the conformance between the transfer data and the pattern program
data.
425101 Output Cnvr Overtime
The PCB transport (carry in) from Cnvr Positioning2 did not end in prescribed
time.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425102 Output Cnvr Overtime
The PCB transport (exhaust) to output machine did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425103 Output Cnvr Overtime
The movement to PCB receiving position did not end in prescribed time.
-----
425104 Output Cnvr Overtime
The movement to the arrangement position did not end in prescribed time.
-----
425105 Output Cnvr Overtime
The PCB transport (carry in) from Cnvr Positioning1 did not end in prescribed
time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425106 Output Cnvr Overtime
The reversal positioning operation did not end in prescribed time.
Por favor, verifique posicionamento da PCB no conveyor e continue a operação
425107 Output Cnvr Overtime
The conveyor upper cover by output side has opened.
Please close the cover. Production can be continued.

31
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425201 Output Cnvr PCB Detection
PCB's were at inlet and outlet of cnvr.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425202 Output Cnvr PCB Detection
There is no PCB on the Cnvr The PCB fell while moving to the receiving position.
Please continue production after checking whether the P.C.B has fallen around a
conveyor. Moreover, please execute the zeroing operation of a pertinent conveyer
from the screen of maintenance/unit adjustment/conveyer when the width of the
conveyer has changed.
425203 Output Cnvr PCB Detection
There is no PCB on the Cnvr The PCB was removed.
-----
425204 Output Cnvr PCB Detection
There is a PCB on the Cnvr The PCB could not be discharged.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425205 Output Cnvr PCB Detection
There is no PCB on the conveyer. After the PCB carrying in ended, it can not able
to be detected.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425206 Output Cnvr PCB Detection
The PCB was detected by the conveyer entrance sensor.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425207 Output Cnvr PCB Detection
The PCB was detected with the conveyer exit sensor.
Please confirm the P.C.B on the conveyer.
425208 Output Cnvr PCB Detection
The exhaust end board sensor of a conveyor exit detected the PCB
Please check the P.C.B on a conveyor.
425209 Output Cnvr PCB Detection
The exhaust end board sensor of a conveyor exit did not detect PCB during
discharge operation.
Please check the sensor.
425210 Output Cnvr PCB Detection
Manual bypass of the PCB was carried out in the state where a PCB is on a
conveyor.
Please remove the P.C.B carried out manual bypass. Production can be
continued.
425211 Output Cnvr PCB Detection
The PCB was not found in the proper position.
Please remove the P.C.B on a conveyor. Production can be continued.
425212 Output Cnvr PCB Detection
Manual bypass of the PCB was carried out.
Please remove the P.C.B carried out manual bypass. Production can be
continued.