SOM-2080-001_w.pdf - 第38页
35 SOM-2080 Erroe ID Error Name, Description, Cause, and Remedy 426201 Output Conveyor Error The initialization is imperfect. ----- 426202 Output Conveyor Error An error occurred during zeroing operation. Try to operate …

34
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
425315 Output Cnvr Error
The PCB was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer. Moreover, please execute the zeroing
operation of a pertinent conveyer from the screen of maintenance/unit adjustment/
conveyer when the width of the conveyer has changed.
425316 Output Cnvr Error
Abnormality occurred at the time of disposal of Board END signals.
Please start production again.
425317 Output Cnvr Error
The process of inside signal between conveyors failed.
Por favor, verifique posicionamento da PCB no conveyor e continue a opera
ção
425318 Output Cnvr Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
426101 Input Conveyor Error
The initialization is imperfect.
-----
426102 Input Conveyor Error
An error occurred during zeroing operation.
Try to operate the zero return again.
426103 Input Conveyor Error
An alarm for interference is occurring.
-----
426104 Input Conveyor Error
DI was detected.
-----
426105 Input Conveyor Error
The input conveyor upper cover opened during product operation or the machine
running.
-----
426106 Input Conveyor Error
Brownout on the power source was detected.
Confirm the transfer driver.
426107 Input Conveyor Error
OT(+) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
426108 Input Conveyor Error
OT(-) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
6.3 Conveyor
1005-001

35
SOM-2080
Erroe ID Error Name, Description, Cause, and Remedy
426201 Output Conveyor Error
The initialization is imperfect.
-----
426202 Output Conveyor Error
An error occurred during zeroing operation.
Try to operate the zero return again.
426203 Output Conveyor Error
An alarm for interference is occurring.
-----
426204 Output Conveyor Error
DI was detected.
-----
426205 Output Conveyor Error
The output conveyor upper cover opened during product operation or the machine
running.
-----
426206 Output Conveyor Error
Brownout on the power source was detected.
Confirm the transfer driver.
426207 Output Conveyor Error
OT(+) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
426208 Output Conveyor Error
OT(-) was detected during product operation or the machine running.
Operate the zero return for the conveyor.
426301 Trapped PCB Detection
There is a PCB between conveyors of the Input and the Positioning.
Remove the P.C.B. on the conveyor.
426302 Trapped PCB Detection
There is a PCB between conveyors of the Positioning and the Output.
Remove the P.C.B. on the conveyor.
426303 Trapped PCB Detection
There is a PCB between conveyors of the input machine and the supply conveyor.
Remove the P.C.B. on the conveyor.
426304 Trapped PCB Detection
There is a PCB between conveyors of the output and the output machine.
Remove the P.C.B. on the conveyor.
6.3 Conveyor
1005-001

36
SOM-2080
6.4 Tray Feeder
Table 6
Erroe ID Error Name, Description, Cause, and Remedy
430101 Erro no travamento da Bandeja
O botão principal de emergência está acionado
Por favor, pressione POWER
430102 Erro no travamento da Bandeja
Tampa aberta
Por favor, feche a tampa
430103 Erro no travamento da Bandeja
Tampa de manutenção aberta [S0504][S0505].
Por favor, fecha a tampa de manutenção
430104 Erro no travamento da Bandeja
Tampa aberta (Down) [S0501]
Por favor, feche a tampa de baixo
430105 Erro no travamento da Bandeja
Tampa aberta (Up) [S0502]
Por favor, feche a tampa de cima
430106 Erro no travamento da Bandeja
Tampa aberta (Middle) [S0503]
Por favor, feche a tampa do meio
430107 Erro no travamento da Bandeja
The pallet chuck was opened while the elevator was working.[B0414,B0416]
Pallet chuck closed detecting sensor B0414,B0416 Confirmation.
430108 Erro no travamento da Bandeja
The pallet Mis-Set was detected while the elevator was working.[0420]
The position of pallet Mis-Set detecting sensor B0420 confirmation.
430109 Erro no travamento da Bandeja
Mis-Pick-up Detection on Pallet[B0417].
Please open the cover and take out the Mis-Pickup component.
43010a Erro no travamento da Bandeja
Mis-Pick-up Detection on Pallet[B0418].
Please open the cover and take out the Mis-Pickup component.
43010b Erro no travamento da Bandeja
Mis-Pick-up Detection on Pallet[B0419].
Please open the cover and take out the Mis-Pickup component.
43010c Erro no travamento da Bandeja
Magazine Rack Shutter was closed while lower elevator was working.[B0421,B04
24,B0425]
Magazine Rack Shutter closed sensor B0421,B0424,B0425 confirmation.
43010d Erro no travamento da Bandeja
Magazine Rack Shutter was closed while lower elevator was working.[B0427,B04
30,B0431]
Magazine Rack Shutter closed sensor B0427,B0430,B0431 confirmation.
6.4 Tray Feeder