Minor Maintenance
Performing Maintenance Tasks Maintenance Tasks for the Conveyor
Maintenance Manual SIPLACE X Series 41
Cleaning and Preserving t he Hexagonal Sha fts
4.4.3.2 Cleaning and Preserving the Hexagonal Shafts
Cleaning the Fixtu re Tape
4.4.3.3 Cleaning the Fixture Tape
Cleaning and Preserving t he Recirculatin g Ball Screws of the Width Adjustment
4.4.3.4 Cleaning and Preserving the Recirculating Ball Screws of the Width Adjustment
Apply Teflon oil to a lint-free cloth and clean the
hexagonal shafts (1) in the conveyor.
Alternatively you can also use a SIPLACE cleansing
tissue.
Repeat the procedure for all hexagonal shafts in the
conveyor.
CAUTION! Risk of cutting!
The fixing strip has a sharp edge.
Clean the fixing strip of the width adjustment
clamping unit using a lint-free cloth moistened with
ethanol.
Clean and preserve the recirculating ball screw (1) by
running a SIPLACE cleansing tissue along the thread
of the screw.
Repeat this procedure for all recirculating ball
spindles on the conveyor.
Minor Maintenance
Maintenance Tasks for the Conveyor Final Work
42 Maintenance Manual SIPLACE X Series
Cleaning and Preserving t he Guide Shafts of the Wid th Adjustment
4.4.3.5 Cleaning and Preserving the Guide Shafts of the Width Adjustment
Cleaning and Pre serving t he Guide Shaft of the Conv eyor Sides
4.4.3.6 Cleaning and Preserving the Guide Shaft of the Conveyor Sides
Final Work
4.4.4 Final Work
Reconnect all clamps, where applicable.
Set back to the original conveyor width.
Apply Teflon oil to a lint-free cloth and clean the
bottom (1) and top (2) guide shaft of the width
adjustment.
Alternatively you can also use a SIPLACE cleansing
tissue.
Repeat the procedure for all width adjustment guide
shafts on the conveyor.
Clean and preserve the guide shaft (1) for the
conveyor sides with a SIPLACE cleansing tissue.
Repeat the procedure for all guide shafts on the
conveyor sides.
Minor Maintenance
Consumables, Spare and Wear Parts, Tools Maintenance Work on the Gantry
Maintenance Manual SIPLACE X Series 43
Maintenanc e Work on the Gantry
4.5 Maintenance Work on the Gantry
Consumables, Spare and Wear Parts, Tools
4.5.1 Consumables, Spare and Wear Parts, Tools
Lint-free cloths [03082092-xx]
Ethanol
Protective latex gloves [00372972-xx]
ESD wristband [00320279-xx]
SIPLACE cleansing tissue [00315253-xx]
Preparatory Steps
4.5.2 Preparatory Steps
There must be no PCBs in the machine during the following maintenance steps.
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 11].
Performing Maintenance Tasks
4.5.3 Performing Maintenance Tasks
See also
1.1.2 Safety Instructions for Working with Strong Magnetic Fields [ ➙ 8]
Cleaning the X Ax is Scale
4.5.3.1 Cleaning the X Axis Scale
CAUTION! Always use soft cloths and minimal
pressure to clean the scales.
Dirty scales can lead to counting errors and, as a
consequence, to machine stoppages.
Clean the incremental scales (1) of the X axes with a
lint-free cloth soaked in ethanol.