X-Series-Maintenance-Manual(1) - 第84页

Major Maintenance Maintenance Tasks for C&P2 0A Head Performing Maintenance Tasks 84 Maintenance Manual SIPLACE X Series Performing Maintenan ce Tasks 5.5.5 Performing Maintenance Tasks Oiling the DP Driver Bearing 5…

100%1 / 118
Major Maintenance
Overview of Lubrication Points Maintenance Tasks for C&P20A Head
Maintenance Manual SIPLACE X Series 83
Overview of Lubrication Points
5.5.4 Overview of Lubrication Points
Z linear guide
2 x 4 µl Lubcon Thermoplex ALN 1001/00 (blue combitip)
per ball groove
DP segment guide
2 x 2 µl Lubcon Thermoplex ALN 1001/00 (blue combitip)
per ball groove at each segment
Driver bearing
C&P20:
1 x 1 µl Nye Synthetic Oil 200A (white combitip) per driver
bearing
C&P20A:
1 x 1 µl Klüberalfa DH 3-100 (black combitip) per driver
bearing
Major Maintenance
Maintenance Tasks for C&P20A Head Performing Maintenance Tasks
84 Maintenance Manual SIPLACE X Series
Performing Maintenance Tasks
5.5.5 Performing Maintenance Tasks
Oiling the DP Driver Bearing
5.5.5.1 Oiling the DP Driver Bearing
C&P20: For this maintenance task, use the white combitip with Nye Synthetic Oil 200A.
C&P20A: For this maintenance task, use the black combitip with Klüberalfa DH 3-100.
Set the multipette to 1 µl.
Rotate the star three times and wipe away any lubricant which appears with the blotting paper.
Fit the removed nozzle back into place.
Remove the blotting paper.
Rotate the star so that segment 1 can be seen in the
center of the service hole.
Carefully push a strip of blotting paper (1) under the
service hole (2) between the head housing and the
raceway. The blotting paper should soak up any
excess oil.
Mark the first segment by removing a nozzle.
Position the multipette on the top edge of the locking
pin and apply 1 µl of lubricant.
Repeat this step for all segments.
Major Maintenance
Performing Maintenance Tasks Maintenance Tasks for C&P20A Head
Maintenance Manual SIPLACE X Series 85
Oiling the DP Segment Guide
5.5.5.2 Oiling the DP Segment Guide
For this maintenance task, use the blue combitip with
Thermoplex ALN 1001/00.
Set the multipette to 2 µl.
Clamp the rubber hose (1) between the Z axis and
the driver of the return unit.
Mark the first segment by removing a nozzle.
Move the segment on the Z axis rotor out as far as the
end stop. Make sure that the driver bearing is in the
center of the jaws.
Apply 2 µl of lubricant to the center of each guide
track (left and right side).