X-Series-Maintenance-Manual(1) - 第9页
Introduction Safety Instructions for the Compressed Air Supply Safety Instructions Maintenance Manual SIPLACE X Series 9 Safety Instr uctions for th e Compressed A ir Supply 1.1.4 Safety Instructions for the Compressed A…

Introduction
Safety Instructions Safety Instructions for Working with Strong Magnetic Fields
8 Maintenance Manual SIPLACE X Series
Safety Instruc tions for Wo rking with Stro ng Magnetic Fie lds
1.1.2 Safety Instructions for Working with Strong Magnetic Fields
Safety Instruc tions for th e Power Supply
1.1.3 Safety Instructions for the Power Supply
▪ This means that some parts of the system carry potentially lethal voltages - even when switched off
at the main power switch.
▪ Incorrect handling of the placement system can therefore result in fatal injuries, severe injuries or
considerable damage to equipment.
▪ Measurements and maintenance work must always be carried out by appropriately qualified
personnel.
▪ Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60 204,
part 1) or the regulations specific to your country.
▪ Before starting any maintenance work, switch off at the main switch and disconnect the machine
from the main power supply.
▪ Always secure the machine against unauthorized reactivation. If these instructions are not followed,
you may be able to touch live parts, which could result in fatal or severe injuries.
Maintaining or replacing assemblies
► End all placement operations on the machine.
► Shut down the Windows operating system correctly, otherwise problems may occur when restarting
or data may be lost.
► Switch the machine off at the main switch.
► Disconnect the machine from the main power supply.
► Switch off the machine and attach warnings signs to indicate that service work is in progress.
DANGER
Strong permanent magnet fields
Fatal hazard: persons with active implants (e.g. pacemakers, defibrillators, insulin pumps etc.)
are at risk from strong permanent magnetic fields inside the machine.
Persons are risk should avoid the immediate vicinity of the machine.
CAUTION
Danger of crushing
Danger of crushing for persons with passive metal implants (e.g. plates, screws).
► Do not reach or lean over into the machine when the protective covers are open.
► Do not bring any metal objects into the hazard area.
CAUTION
Strong permanent magnet fields
There is a risk that the strong magnetic fields could corrupt data on data media or check cards.
► Keep sensitive data carriers away from the permanent magnets.
WARNING
Hazardous Voltages!
The machine is supplied with 3 x 400 V~ (or 3 x 204 V~ / 3 x 230 V~ / 3 x 380 V~ / 3 x 415 V~)
± 5 %, 50/60 Hz mains voltage.
► Observe the safety instructions in the user manual during all service work!

Introduction
Safety Instructions for the Compressed Air Supply Safety Instructions
Maintenance Manual SIPLACE X Series 9
Safety Instr uctions for th e Compressed A ir Supply
1.1.4 Safety Instructions for the Compressed Air Supply
Safety Instr uctions for Wo rk on the Cut ting Device
1.1.5 Safety Instructions for Work on the Cutting Device
Safety Instruc tions for th e Gantry
1.1.6 Safety Instructions for the Gantry
CAUTION
Risk of injury from compressed air!
Risk of injury when disconnecting the compressed air lines.
► NEVER disconnect compressed air lines while they are still pressurized.
CAUTION
Prolonged interruptions to the compressed air supply can cause damage.
When the machine is switched on, do not use the shutoff valve to interrupt the compressed air
supply for more than 30 minutes.
► If you need to shut off the compressed air system for longer, in order to carry out
maintenance or servicing work, you must switch the machine off at the main switch and
disconnect it from the power supply.
WARNING
Risk of injury when working near the cutter.
If you wish to work on the tape cutter, disconnect the machine from the mains supply and
compressed air supply.
► Wait until the operating pressure has dropped to 0 MPa.
► Always secure the machine against unauthorized reactivation.
CAUTION
Risk of injury when performing service work on the cutter.
Never support the cutter on your body, e.g., on your knees or thighs. Do not place your feet
under the cutter.
► Wear appropriately thick protective gloves.
► When removing/fitting the cutter, hold it only on the left and right, on the outside.
CAUTION
Moving the gantry can damage the placement head.
When moving the gantry, observe the following:
► NEVER move the gantry by pushing with your hands against the placement head.
► NEVER push the gantry while the Z axis is lowered.

Introduction
Safety Instructions Safety Instructions for Maintenance Tasks
10 Maintenance Manual SIPLACE X Series
Safety Instruc tions for Main tenance Tasks
1.1.7 Safety Instructions for Maintenance Tasks
WARNING
Danger of burning
► Never use alcohol for cleaning purposes when working in the vicinity of a naked flame or
fire.
► Never spray lubricants or cleaning agents from aerosol cans in the vicinity of a naked flame
or fire.
CAUTION
Ethanol
► Always wear safety goggles and gloves when using concentrated ethanol to clean modules.
► If ethanol should accidentally get into your eyes, rinse your eyes immediately with water.
CAUTION! SIPLACE cleaning tissue
Harmful: may cause lung damage if swallowed.
Do not inhale vapor / aerosol.
Avoid contact with the skin. If swallowed, do not induce
vomiting. See medical attention immediately and show
the packaging or label.
Wear latex gloves while using the cleaning tissue.
CAUTION
Consumable materials
Observe the safety data sheets for consumable materials!
CAUTION
Cleaning and lubrication
► Always use ethanol for cleaning – do not use solvents.
► NEVER use compressed air to clean units inside the placement machine or modules.
CAUTION
Danger of cutting on the IC and FC camera
There is a risk of cutting your fingers along the edges of the mirror.
► Wear laboratory gloves as protection and avoid touching the edges.
► The laboratory gloves are also required for effective cleaning (fingerprints!).
CAUTION
Only one person must be present at each component preparation station at any given time.
This is to ensure the safety of the operator and the safety of the second person. Pulling in the
component trolley is a two-handed operation, so only one person can be reliably protected from
the possible risks.