X-Series-Maintenance-Manual(1) - 第94页

Major Maintenance Maintenance Tasks for CPP Head Preparatory Steps 94 Maintenance Manual SIPLACE X Series Removing the placement head ► Dismantle the placement head and remove it from t he placement m achine. Read the se…

100%1 / 118
Major Maintenance
Consumables, Spare and Wear Parts, Tools Maintenance Tasks for CPP Head
Maintenance Manual SIPLACE X Series 93
Maintenance Tasks for CPP Head
5.6 Maintenance Tasks for CPP Head
Consumables, Spare and Wear Parts, Tools
5.6.1 Consumables, Spare and Wear Parts, Tools
Starter kit for maintenance CPx and TwinHead [03071171-03]
Universal placement head mounting rack [03056231-xx]
Set of Allen wrenches
Set of open-jawed spanners
Cotton wool buds [00352931-xx]
Second multipette, if required [00386154-xx]
Vacuum hose DP/CPP, if required [03015920Sxx]
Silencer for CPP, if required [03061440-xx]
Component sensor protective cap [03080984-xx]
Service manual for your maschine:
SX1/SX2/DX1/DX2: [00196496-xx] (German), [00196497-xx] (English) or
SX4/DX4: [00196712-xx] (German), [00196713-xx] (English) or
X-Serie: [00194439-xx] (German), [00194440-xx] (English)
You will find all key tools and consumable materials for maintenance work on the TwinHead, CPP and
C&P20(A) heads in the "Starter kit for maintenance CPx and TwinHead" [03071171-03].
Preparatory Steps
5.6.2 Preparatory Steps
Assembling the head mount
Assemble the head mount. Read the head mount manual (German and English: [00196371-xx]).
Connect the assembly mount ESD connection to an ESD connection at the workplace.
Vacuum test
Set the nozzles for the current nozzle configuration down in the nozzle changer.
Before you begin maintenance work, perform a vacuum test. Use the calibration nozzles 2057 for
this. If vacuum value irregularities occur at certain segments, take a closer look at these during
maintenance work. Note down the numbers of the problematic segments for later reference.
CAUTION
ESD regulations!
Always observe the ESD regulations described in the user manual.
Major Maintenance
Maintenance Tasks for CPP Head Preparatory Steps
94 Maintenance Manual SIPLACE X Series
Removing the placement head
Dismantle the placement head and remove it from the placement machine. Read the service manual
for the respective machine first.
Fit the placement head onto the head mount.
Dismantling the front plate
Dismantle the front plate of the CPP head. Read the service manual for the respective machine first.
Multipette
Prepare the multipette. (See below)
Color-coding of dosage devices and lubricants
See also
1.2 Preparatory Work... [ ➙ 11]
Fit the protective cap onto the component sensor for
the placement head.
NOTICE
Fast Head Exchange (FHE)
If possible, use the FHE function. This enables you to perform a brief calibration during the
subsequent installation.
CAUTION
Do not combine!
Only use the combitip specifically marked for each lubricant, to avoid combining the lubricants.
Contamination (combination) of lubricants can affect the service life of the bearings!
Color Lubricant Application
Green Green combitip
Isoflex Topas NCA 5051
Star bearing
Black Black combitip
Klüberalfa DH 3-100
Driver bearing
Blue Blue combitip
Lubcon Thermoplex ALN 1001/00 50 ml
Segment guide/Z axis guide
Yellow Yellow combitip
Klüber oil GEM 1 220 N
Support roller
Major Maintenance
Preparatory Steps Maintenance Tasks for CPP Head
Maintenance Manual SIPLACE X Series 95
Overview of M ultipette
5.6.2.1 Overview of Multipette
Assembling the Multipette
5.6.2.2 Assembling the Multipette
1. Multipette
2. Filling lever
3. Dosage lever
4. Reject button
5. Volume setting
6. Digital display
This shows the application amount. The amount
applied depends on the combitip used and the
current position of the volume setting.
7. Combitip
Press the filling lever on the multipette right down and
hold in position.
Press the relevant combitip onto the multipette until it
engages.
Check whether the combitip is fitted firmly on the
Multipette.
Set the required dosage on the volume setting.