4OM-1054-002 - 第172页

Error ID Item Description 060601 T able-Y Axis Servo Alarm Emergency stop 060602 T able-Y Axis Servo Alarm Encoder error 060603 T able-Y Axis Servo Alarm Mechatrosink cut error 060604 T able-Y Axis Servo Alarm Location t…

100%1 / 337
Error ID Item Description
0605cb Table-Y Axis Servo Alarm Encoder echoback error. [Shutdown touch sw key and
mainbreaker sw off.]
0605cc Table-Y Axis Servo Alarm Multiturn limit disagreement
0605d0 Table-Y Axis Servo Alarm Position error pulse overflow
0605e0 Table-Y Axis Servo Alarm No option
0605e1 Table-Y Axis Servo Alarm Option time out
0605e2 Table-Y Axis Servo Alarm Option WDC error
0605e5 Table-Y Axis Servo Alarm WDT error
0605e6 Table-Y Axis Servo Alarm Communication error
0605ea Table-Y Axis Servo Alarm Servo pack error
0605eb Table-Y Axis Servo Alarm Servo pack access error
0605ec Table-Y Axis Servo Alarm Servo pack WDC error
0605ed Table-Y Axis Servo Alarm Command not execute
0605f1 Table-Y Axis Servo Alarm Power line open phase
060591 Table-Y Axis Servo Alarm Overload warning
060592 Table-Y Axis Servo Alarm Regenerative overload warning
060594 Table-Y Axis Servo Alarm Data setting warning
060595 Table-Y Axis Servo Alarm Command warning
060596 Table-Y Axis Servo Alarm Communication warning
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0111-003 2-54 AGS01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
060601 Table-Y Axis Servo Alarm Emergency stop
060602 Table-Y Axis Servo Alarm Encoder error
060603 Table-Y Axis Servo Alarm Mechatrosink cut error
060604 Table-Y Axis Servo Alarm Location timeout
060605 Table-Y Axis Servo Alarm Position error pulse overflow error
060606 Table-Y Axis Servo Alarm Software limit (-)
060607 Table-Y Axis Servo Alarm Software limit (+)
060608 Table-Y Axis Servo Alarm Illegal parameter
060609 Table-Y Axis Servo Alarm System error
06060a Table-Y Axis Servo Alarm Illegal command
06060b Table-Y Axis Servo Alarm Servo on time out
06060c Table-Y Axis Servo Alarm Servo off time out
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
060701 Table-Y Axis Interlock Movement cannot take place until the index angle is adjusted.
060702 Table-Y Axis Interlock Movement cannot take place until the x/y chute is at
correct position.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
060801 Table-Y Axis Communication Communication error was detected.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0111-003 2-55 AGS01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
070502
XY C onveyor Axis Servo Alarm
User constant breakdown. [Shutdown touch sw key and
mainbreaker sw off.]
070503
XY C onveyor Axis Servo Alarm
Main circuit encoder error
070504
XY C onveyor Axis Servo Alarm
User constant setting error. [Shutdown touch sw key and
mainbreaker sw off.]
070505
XY C onveyor Axis Servo Alarm
Combination error
070510
XY C onveyor Axis Servo Alarm
Overcurrent or Heat Sink Overheated. [Shutdown touch sw
key and mainbreaker sw off.]
070530
XY C onveyor Axis Servo Alarm
Regeneration error detected
070532
XY C onveyor Axis Servo Alarm
Regenerative overload
070540
XY C onveyor Axis Servo Alarm
Overvoltage
070541
XY C onveyor Axis Servo Alarm
Undervoltage
070551
XY C onveyor Axis Servo Alarm
Overspeed
070571
XY C onveyor Axis Servo Alarm
Overload: high load
070572
XY C onveyor Axis Servo Alarm
Overload: low load
070573
XY C onveyor Axis Servo Alarm
Dynamic break overload
070574
XY C onveyor Axis Servo Alarm
Overload of Surge Current Limit Resistor
07057a
XY C onveyor Axis Servo Alarm
Heat sink overheated
070581
XY C onveyor Axis Servo Alarm
Encoder backup error. [Shutdown touch sw key and
mainbreaker sw off.]
070582
XY C onveyor Axis Servo Alarm
Encoder checksum error. [Shutdown touch sw key and
mainbreaker sw off.]
070583
XY C onveyor Axis Servo Alarm
Absolute encoder battery error
070584
XY C onveyor Axis Servo Alarm
Encoder data error. [Shutdown touch sw key and mainbreaker
sw off.]
070585
XY C onveyor Axis Servo Alarm
Encoder overspeed
070586
XY C onveyor Axis Servo Alarm
Encoder overheated
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
01 1 1-003 2-56 AGS01ETRP
3.3 Error IDs and Remedial Procedures