4OM-1054-002 - 第265页

3.3 Error IDs and Remedial Procedures Error ID ltem Description 660101 Nozzle Recog. Recognition Error Code Note: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display . 660201 Nozzle Skip N…

100%1 / 337
Error ID ltem Description
650601 Head Origin Offset Total Designate Loop Exceeded Time.
(Cause 1) Each head deviated from its origin position in comparison with the master head.
(Remedy 1) Check if the master head is not loose.
650701 Comp. Thickness Teach Component Thickness Was Less Than Tolerance.
650702 Comp. Thickness Teach Component Thickness Was More Than Tolerance.
(Cause 1) A mistake is found in the component thickness data of the component library data.
(Remedy 1) Set the component thickness data correctly.
650801 Recog. Data Teach Recognition Error Code.
650901 Trash Teach Error Code. Recognition Error Code.
Note: Refer to "4. Troubleshooting on Recognition System" for details.
3.3 Error IDs and Remedial Procedures
0307-004 2-147 AGS01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
660101 Nozzle Recog. Recognition Error Code
Note: Refer to "4.3.4 Nozzle Recognition Errors" for the detailed error display.
660201 Nozzle Skip Nozzle Down Error (L)
660202 Nozzle Skip Nozzle Down Error (H)
660203 Nozzle Skip Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
660204 Nozzle Skip Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
660205 Nozzle Skip Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
0307-004 2-148 AGS01ETRP
3.3 Error IDs and Remedial Procedures
Error ID ltem Description
660206 Nozzle Skip Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master nozzle in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
660207 Nozzle Skip Nozzle Drop
(Cause 1) When a "NOZ. DOWN ERR (L)" error occurs, the nozzle is bypassed and the nozzle
bypass data indicates that "BYPASSED" appears as a low nozzle item.
(Remedy 1) Open the "Head/Noz. Bypass" tab sheet in the "OPN. MODE" window (submenu)
and press the [Reset Noz. Bypass] button. The "Bypass" in the "Nozzle Height"
text box disappears, indicating that "Bypass" is canceled.
660208 Nozzle Skip Dummy Nozzle
660209 Nozzle Skip Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the "Head/Noz. Bypass" tab
sheet of the "OPN. MODE" window (submenu), the manual bypass designation
of all nozzles is all canceled.
66020a Nozzle Skip Nozzle Change Error.(Cam lock action)
66020b Nozzle Skip Nozzle Change Error.(Cam Free action)
66020c Nozzle Skip Cam Origin Error.
66020d Nozzle Skip Nozzle Teach Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-004 2-149 AGS01ETRP