4OM-1054-002 - 第300页

Recognition Error ID Item Description 0139324202 Error in "Component Library Outward Length T ol" ---- Data (Cause) Wrong parameters are set. (Remedy) Set correct parameters. 0139325101 "Component Library …

100%1 / 337
Recognition Error ID Item Description
0139320004 Error in "Component Library Front ltg algo" Data ----
0139320005 Error in "Component Library Back ltg algo" Data ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139320007 "Component Library View Range Set" Not ----
Supported!
0139322001 "Component Library Polarity Detn" ----
Not Supported!
0139322002 "Component Library Polarity Inspection Method" ----
Not Supported!
0139322003 "Component Library Polarity Detn Inspection ----
Pos X or Y" Not Supported!
0139322004 "Component Library Polarity Detn Inspection ----
Range" Not Supported!
0139323001 "Component Library Upper/Lower Surface Detn" ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
013934102 Error in "Component Library Mold Size ----
Tolerance X or Y" Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139324201 "Component Library Outward Length Detn" Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
4.3 Recognition Error IDs and Remedial Procedures
0307-005 2-182 AGS01ETRP
Recognition Error ID Item Description
0139324202 Error in "Component Library Outward Length Tol" ----
Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139325101 "Component Library Lead Width Detn" Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139325102 "Component Library Lead Posn (Latl Dir) Detn" ----
Not Supported!
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139325201 "Component Library Lead Posn (Latl Dir) Detn" ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139325202 Error in "Component Library Lead Posn ----
(Latl Dir) Tol" Data.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
0307-005 2-183 AGS01ETRP
Recognition Error ID Item Description
0139325301 "Component Library Lead Posn (Long Dir) Tol" ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139325302 Error in "Component Library Lead Posn(Long Dir) ----
Tol" Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139326101 "Component Library Electd Pos Detn" Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139326102 Error in "Component Library Electd Pos Tol" Data ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139326201 "Component Library Electd Size Detn" Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139326202 Error in "Component Library Electd Size Tol" Data ----
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
4.3 Recognition Error IDs and Remedial Procedures
0307-005 2-184 AGS01ETRP