(8) Light Source Device for Component Recognition 1.3 Maintenance Spots 021 1-004 1-19 AGS01ETRP Fig. 4A18 Fig. 4A19

Fig. 4A17 X/Y Table Section
1.3 Maintenance Spots
0211-004 1-18 AGS01ETRP

(8) Light Source Device for Component Recognition
1.3 Maintenance Spots
0211-004 1-19 AGS01ETRP
Fig. 4A18
Fig. 4A19

(9) Head Section
1.3 Maintenance Spots
0307-006 1-20 AGS01ETRP
Fig. 4A20
Vacuum Nozzle 3M7
Every 3 Months Inspection
Check the condition of the vacuum nozzle. When the
nozzle end is worn out, replace it with a new one.
Note: Refer to "1.4 Maintenance Method" for the
detailed information on how to detach or attach
the vacuum nozzle.
Diffusion Plate 1M1
Every Month Cleaning
When dirt and dust have accumulated on the lower
surface of the diffusion plate, wipe them off with the
lens cleaning cloth (the standard accessory part).
Note: Never use neither solvent nor ethanol.
Otherwise, the diffusion plate may crack.
Vacuum Nozzle 1W7
Every Week Cleaning
• Clean the tapered area of the nozzle with a lens
cleaning cloth (standard accessory part).
• Detach the nozzle and blow air to remove dirt and
dust.
Note: When the nozzle is heavily stained, detach and
clean it with an ultrasonic cleaner or a rag
soaked in alcohol.
If alcohol is used with the nozzle being attached,
it will adhere to the diffusion plate, causing the
plate to crack.
Refer to "1.4 Maintenance Method" for details.
Diffusion Plate 1W6-1
Every Week Inspection/Cleaning
Check that no grease adheres to the upper surface of
the diffusion plate.
If necessary, wipe off the grease with a clean and dry
rag.
Note: Never use neither solvent nor ethanol.
Otherwise, the diffusion plate may crack.