4OM-1054-002 - 第34页

Fig. 4A22 0303-005 1-21 AGS01ETRP 1.3 Maintenance Spots Cam Follower Opening of Head Cap Miniature Stroke Bearing 1M2 Every Month Inspection/Lubrication (DAPHNE EPONEX GREASE No. 1) Move the cam follower to the lowest po…

100%1 / 337
(9) Head Section
1.3 Maintenance Spots
0307-006 1-20 AGS01ETRP
Fig. 4A20
Vacuum Nozzle 3M7
Every 3 Months Inspection
Check the condition of the vacuum nozzle. When the
nozzle end is worn out, replace it with a new one.
Note: Refer to "1.4 Maintenance Method" for the
detailed information on how to detach or attach
the vacuum nozzle.
Diffusion Plate 1M1
Every Month Cleaning
When dirt and dust have accumulated on the lower
surface of the diffusion plate, wipe them off with the
lens cleaning cloth (the standard accessory part).
Note: Never use neither solvent nor ethanol.
Otherwise, the diffusion plate may crack.
Vacuum Nozzle 1W7
Every Week Cleaning
Clean the tapered area of the nozzle with a lens
cleaning cloth (standard accessory part).
Detach the nozzle and blow air to remove dirt and
dust.
Note: When the nozzle is heavily stained, detach and
clean it with an ultrasonic cleaner or a rag
soaked in alcohol.
If alcohol is used with the nozzle being attached,
it will adhere to the diffusion plate, causing the
plate to crack.
Refer to "1.4 Maintenance Method" for details.
Diffusion Plate 1W6-1
Every Week Inspection/Cleaning
Check that no grease adheres to the upper surface of
the diffusion plate.
If necessary, wipe off the grease with a clean and dry
rag.
Note: Never use neither solvent nor ethanol.
Otherwise, the diffusion plate may crack.
Fig. 4A22
0303-005 1-21
AGS01ETRP
1.3 Maintenance Spots
Cam Follower
Opening of Head Cap
Miniature Stroke Bearing 1M2
Every Month Inspection/Lubrication (DAPHNE EPONEX GREASE No. 1)
Move the cam follower to the lowest position.
Push up the vacuum nozzle and release your finger. When the vacuum nozzle does not
move down smoothly, cleaning and lubrication are required.
Note: Refer to "1.4.5 Disassembly, Cleaning, and Lubrication of Miniature Stroke
Bearing".
Miniature Stroke Bearing 6M11
Every 6 Months Cleaning
Refer to "1.4.5 Disassembly, Cleaning, and Lubrication of Miniature Stroke Bearing"
and wash the MSB shaft and outer cylinder with kerosene for 5 to 10 minutes, using
the ultrasonic cleaner.
When the upper and lower seals are scratched or deformed or foreign substances
have accumulated on them, replace them with new ones (630 048 0849).
Fig. 4A21
1.3 Maintenance Spots
0211-004 1-22 AGS01ETRP
(10) Linear Measure Detection Section
Fig. 4A23
Fig. 4A24