4OM-1054-002 - 第65页

*3 *4 *5 *6 *7 *1 *2 (1-2) Open the "Noz Cleaning" tab sheet. (Operation Sequence: "UNIT ADJ." Window (Submenu) Æ "Nozzle Adj." T ab Æ "Noz Cleaning" T ab Sheet) Fig. 4A64 "No…

100%1 / 337
1.4.4 Detachment and Attachment of Vacuum Nozzle
Before detaching or attaching a vacuum nozzle, be
sure to spread a rag under the working area.
Otherwise, a fallen vacuum nozzle will easily be lost if
any.
(1) Detachment of Vacuum Nozzle
(1-1) Set the [OPERATION] switch to the "SETUP" side.
Confirm that the "LOCK" lamp on the front operation panel is "ON".
The vacuum nozzles must be detached or attached
with the operation power being turned "ON".
It is dangerous. Be sure to detach or attach a
vacuum nozzle alone.
CAUTION
0303-005 1-50 AGS01ETRP
1.4 Maintenance Method
CAUTION
*3
*4
*5
*6
*7
*1
*2
(1-2) Open the "Noz Cleaning" tab sheet. (Operation Sequence:
"UNIT ADJ." Window (Submenu) Æ "Nozzle Adj." Tab Æ
"Noz Cleaning" Tab Sheet)
Fig. 4A64 "Noz Cleaning" Tab Sheet
(1-3) Select the [Move the X/Y Table] button (*4) and press the
[ON] button (entitled "MOVE"). In 2 seconds, press the
[ENABLE] button on the operation panel.
The X/Y Table moves from the cleaning position to the es-
cape position.
(1-4) Press one of the buttons (*1) that corresponds to the head #
where the nozzles to be cleaned are attached and one of the
buttons (*2) to specify the nozzle to be cleaned.
Select the [Designated Hd/Noz Align] button (*3) and press
the [ON] button (entitled "MOVE"). In 2 seconds, press the
[ENABLE] button on the operation panel.
The nozzle is shifted to the position (the front side of the
machine) where it can easily be cleaned.
To detach a nozzle on the desired head, press the
corresponding [Head #] button.
1.4 Maintenance Method
0303-005 1-51 AGS01ETRP
(1-5) Detachment of Vacuum Nozzle
Push the bottom of the nozzle removal jig gently and set it on the vacuum
nozzle such that the hook is engaged correctly with the two-plane cham-
fered side of the vacuum nozzle.
The nozzle removal jig cannot be used for nozzle type 031 (φ6
nozzle). Detach the nozzle by hand.
Fig. 4A65
(1-6) Pull down the nozzle removal jig to detach the vacuum nozzle.
(a) Do not score the diffusion plate while detaching
a vacuum nozzle.
(b) A miniature stroke bearing is used at the
nozzle up/down movement section which
consists of the shaft, the retainer cage, and the
external cylinder units.
When the section is disassembled by mistake,
be sure to correctly reassemble each unit
which belongs to the section.
When the nozzle is detached, the miniature
stroke bearing and the shaft section should not
be removed.
1.4 Maintenance Method
Fig. 4A64-1
Fig. 4A66
Avoid getting the removed vacuum nozzle
magnetized.
When the nozzle is magnetized, an error will occur
in component pick-up or placement.
CAUTION
0303-005 1-52 AGS01ETRP