00192231-09_VD_SSW 407.05_de en - 第20页

Software Version Description, Station Software Version 407.05 07/2008 Edition New functions: - "Alle ablegen" (Return all): All the nozzles on the head are returned to the relev ant magazine. If this is not pos…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
New functions:
- "Alle Magazine quittieren" (Confirm all magazines):
The operator confirms that he/she has reconfigured all magazines of the nozzle changer according
to the specification.
- "Magazine belegen..." (Occupy magazines...) (Was previously "Refill magazine"):
In a dialog box, the operator can specify the number of nozzles contained in a magazine which is not
completely filled. The prerequisite for this is that the garages of the magazine are filled with no gaps
starting at position 1.
Note:
This button is only active if a magazine is not occupied by mixed nozzles and if it does not need to
be reconfigured.
2. Garage occupancy and associated functions
The following information is displayed in the list for all the garages of the selected magazine:
- Garage number
- Garage occupancy (-: empty / 1: occupied)
- Nozzle number of the nozzle currently occupying the magazine
2
- Nozzle number of the specified nozzle
- Indication if the specified occupancy deviates from the actual occupancy and reconfiguration of the
garage is necessary.
New functions:
- "Garage quittieren" (Confirm garage) - (previously only for C&P6 magazines):
The operator confirms that he/she has reconfigured the garage according to the specification.
- "Garage belegen..." (Occupy garage...) (new):
A dialog box allows the operator to set the selected garage to full or empty.
3. Head occupancy:
When switching to the view "Nozzle changer configuration, revolver head", all the nozzles of the relevant
head are no longer returned automatically. Instead, the nozzle configuration on the head is displayed in a
separate list. The operator has the option of returning or discarding the nozzles manually with the following
functions:
2
If no nozzle type has been specified for a garage, 0 is displayed. If a garage is not occupied, "-" is displayed.
19 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
New functions:
- "Alle ablegen" (Return all):
All the nozzles on the head are returned to the relevant magazine. If this is not possible because the
nozzle changer configuration has been changed, the nozzles are discarded into the reject bin.
- "Alle wegwerfen" (Discard all):
All nozzles are discarded into the reject bin.
5.5.2 Revised traceability "Trace +"
A range of improvements with respect to ease of use have been introduced since Traceability 407.03.
5.5.2.1 Requirements
SMV software 6.6.34 or later
(For installation instructions and documentation, see
SMV CD-ROM V6.6.34\win\library\HTMLHelp)
5.5.2.2 "Scan xx" function
To provide additional help for operators, an additional "Scan xx" specification should appear on the station
monitor under certain circumstances: The "xx" refers to the track number on the barcode track scale to be
scanned during component verification.
The "Scan xx" specification appears:
On all track error messages, e.g.
Track error: 3404 Track empty PLCC44 Loc.:3, 7-2 Seg:0
(Scan 9) #E:1
In this example, the operator must scan track 9 on the barcode track scale during refilling.
This feature is only active if component verification is active.
In an additional new "Scan" column
The "Scan xx" specification also appears in two further places:
- in the track error lists
- in the component level indicator
20 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.5.2.3 Support for the track status on the SMV screen
Tracks which have been verified positively during component verification are indicated by a green "9" on the
SMV screen. Previously, this icon was also displayed if the corresponding track has been deactivated as a
result of a detected splice. In future, tracks which are verified positively but deactivated on the station will be
indicated by "(9)".
5.5.2.4 Batch status function in the GUI
The component level indicator has a new column "Status" to display the data recording status of the track
with respect to Traceability.
Only tracks subject to component verification are supported.
Contents of the "Status" column:
<empty> means: no batch data available
means: 1 verified batch
X means: 1 verified batch, track deactivated because follow-on batch is missing (e.g. after
detected splice)
means: 2 verified batches
means: 2 verified batches, transitional area, both batches are logged
The content of the batch data, i.e. the recorded barcodes are not shown.
5.5.2.5 Sort sequence the component level indicator
Clicking on the "Location" column now sorts as follows:
- Sort by location
- within the location by track number
- then by division number
If the component level indicator is opened again, the sort sequence selected previously is still active. (This
does not apply after a reboot).
21 of 104