"Repair" of a batch which has been started:
Re-enter the data with "New Table" + manual correction of component level
"Repair" of a spliced reel, splice still before the sensor:
Re-enter the data of the old batch with "New Table" + refill the new batch + manual correction of component
level
"Repair" of a spliced reel, splice still before the sensor:
Step forward to the new batch, re-enter next batch with "New table"
"Repair" of a spliced reel, splice after the sensor:
Step forward to the new batch, re-enter next batch with "New table"
5.5.2.8 Setup names of up to 50 characters
In conjunction with SMV Version 6.6.34 (or later) it is possible to use setup names of up to 50 characters
(was previously 20 characters).
5.5.3 2321m embedded software for ICOS MVS 340
As of version 407.04, the embedded software 2321m is used by default on machine types SIPLACE F
5
,
SIPLACE S23 and SIPLACE F5HM. This version is required as a result of the revised hardware (MVS 340
Rev. 6). Downloading an older version of the embedded software onto this hardware would render it
unusable. All older releases of the MVS 340 can be operated with the new embedded software.
23 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.6 New Functions in 407.03
Software version 407.03 is based on Version 407.02 and comprises all the functions and error corrections
for this version together with the service packs created for Version 407.02. Version 407.03 of the software
also incorporates the following new features and changes:
Windows XP operating system for the station computer
Support for Traceability SOKO "Threshold value and activation"
Maintenance tasks and elimination of errors
5.6.1 Windows XP operating system for the station computer
Version 407.03 makes it possible to use the Windows XP operating system for SIPLACE machines. This
takes the constantly changing state of hardware into account. Of course, the Windows NT 4.0 operating
system that was previously used is still fully supported.
Operation of the station is identical for both operating systems. There are some minor changes with regard
to installing the station software; these are dealt with in the section
9.3.
The only difference to Version 407.02 is that the operating system uses a different mandatory screen
resolution of 800 * 600 (previously 640 * 480). On older monitors this can lead to a bad picture quality. In this
case it is recommended to exchange the monitors.
5.6.2 Software support for the "Threshold value and activation" Special Design
Version 407.03 supports the "Traceability SUA" special design. This enables traceability to be enabled for
selected components. Interface definitions, prerequisites for the special design and operation are described
in the 407.02 Traceability Manual.
For further information and to order the special design, contact L&A EA CS AP SOKO.
Changes to the Traceability option in connection with the station software "Traceability SUA" special design:
The previous threshold value "Components" on the component level indicator has been replaced with
"Remaining length in mm". This deactivates the relevant track as soon as the remaining length of the
tape (measured from the pickup position) falls below the threshold. Since a feeder has a length of
approximately 500 mm, the threshold values should accordingly be set higher than this value.
Caution: The threshold value "Remaining length in mm" may only be activated
when the Traceability option is installed.
Caution: For this threshold value to function correctly, the feeder pitch must have been entered
correctly
24 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
It is now possible to activate deactivated feeder tracks by clicking on the button "Selected track" in the
empty feeders view. The action is checked by the traceability function and if necessary the feeder track
is deactivated again. Traceability must be active and SMV must be configured to enable this. This
feature is selectable.
Writing to the traceability file on the host system has been improved.
The subpanel name is listed in the traceability file. (only in connection with the "lange Bpos" LR special
design. Caution: GEM is no longer supported in this context.)
The placement position comment is listed in the Traceability file. This feature is selectable.
A batch change is carried out on surf tape feeders without any transition area (only in conjunction with
SMV). This type of batch change is only valid for surf tape feeders that have become empty. Therefore,
these feeders are no longer monitored by the component level indicator facility and no longer appear
there. This feature is selectable.
Traceability without PCB barcode readers. If no PCB barcode reader has been configured, a PCB
barcode does not have to be entered manually. "NoPCBBC_x" is used as a replacement to the barcode,
where x is the internal sequence number of the PCB. This feature is selectable.
If the station name on the station is empty, the IP address (of SrHost) of the station is written to the
traceability file instead.
A triple splice sensor can be used for a dual conveyor.
For further information and to submit an order, contact L&A EA CS AP SOKO.
25 of 104