Software Version Description, Station Software Version 407.05 07/2008 Edition 5.7 New Functions in 407.02 Version 407.02 of the software is based on version 407.01 and incorporates all the functions and bugfixes of versi…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
It is now possible to activate deactivated feeder tracks by clicking on the button "Selected track" in the
empty feeders view. The action is checked by the traceability function and if necessary the feeder track
is deactivated again. Traceability must be active and SMV must be configured to enable this. This
feature is selectable.
Writing to the traceability file on the host system has been improved.
The subpanel name is listed in the traceability file. (only in connection with the "lange Bpos" LR special
design. Caution: GEM is no longer supported in this context.)
The placement position comment is listed in the Traceability file. This feature is selectable.
A batch change is carried out on surf tape feeders without any transition area (only in conjunction with
SMV). This type of batch change is only valid for surf tape feeders that have become empty. Therefore,
these feeders are no longer monitored by the component level indicator facility and no longer appear
there. This feature is selectable.
Traceability without PCB barcode readers. If no PCB barcode reader has been configured, a PCB
barcode does not have to be entered manually. "NoPCBBC_x" is used as a replacement to the barcode,
where x is the internal sequence number of the PCB. This feature is selectable.
If the station name on the station is empty, the IP address (of SrHost) of the station is written to the
traceability file instead.
A triple splice sensor can be used for a dual conveyor.
For further information and to submit an order, contact L&A EA CS AP SOKO.
25 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.7 New Functions in 407.02
Version 407.02 of the software is based on version 407.01 and incorporates all the functions and bugfixes of
version 407.01 and its service packs. Version 407.02 of the software also incorporates the following new
features and changes:
A Polish user interface
Integration of the "track empty max." special design
Support for the "high components" special design
Support for the "traceability" special design
Support for the "2D barcode" special design
Revision of the user interface and improved fiducial and ink spot recognition
Maintenance and error elimination
5.7.1 Polish User Interface
As of version 407.02, the user interface offers Polish in addition to the languages that have been
available up to now.
5.7.2 Support for the "Traceability" Special Design
Version 407.02 supports the "traceability" special design. Traceability can thus be achieved for selected
components. The definition of the interfaces, the prerequisites for the special design and the handling are
described in the Traceability manual.
To obtain further information or order the special design, please contact L&A EA CS AP SOKO.
5.7.3 Software Support for the "2D Barcode" Special Design
Version 407.02 supports Omnitron 2D barcode readers.
However, the following restrictions continue to apply:
Length of the barcodes: max. 25 characters
PCB barcode operation continues to be supported only for a single conveyor.
To obtain further information or order the special design, please contact L&A EA CS AP SOKO.
26 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.7.4 Integration of the "Track Empty Max." Special Design
The integration of the "track empty max." special design gives you the flexibility of being able to adjust the
number of pick-up attempts to be made for the components to be placed. A value of 1, 2 or 3 can be
selected.
All values outside this range are limited to the lowest or highest value, as appropriate.
The setting is made by a service engineer in the "ref_lauf.ma" machine file (see sample file) and requires the
machine to be restarted manually.
{
\ File \ "REF_LAUF.MA"|
\ Version \ "70.407.mdd"|
\ Machine type \ "80F4"|
\ MA-Data: Options Referencerun \
\ \
\ Gantry Referencerun \ 1,
\ Vacuum Referencerun \ 1,
\ Hight Referencerun \ 1,
\ Repetitions Hight Referencerun \ 3,
\ \ 0, Í Parameter to be changed (without description)
\ \ 0,
\ \ 0,
\ \ 0,
\ \ 0,
\ \ 0,
\ \ 0,
\ \ 0
}
Note: The value set applies to all components to be placed.
There will be a different pick-up behavior until track-empty error between C&P and IC Head.
C&P Head:
It is not possible to avoid the first retry of the nozzle to get a component. The nozzle will try to pick up a
second time to get a component, even though there is a "1" entered for the parameter. If the parameter is "2"
the track empty error will occur as supposed after the real second pick up retry. So, there is no difference in
the behavior between entering a "1" or a "2".
IC Head:
Here the track-empty error will occur after the number of retries entered in ref_lauf.ma.
27 of 104