00192231-09_VD_SSW 407.05_de en - 第31页

Software Version Description, Station Software Version 407.05 07/2008 Edition SIPLACE F5HM File Variable Description / Restriction KONFIG_L.MA Sensor system IDs/gantry group 0 Change to gantry group 1 (00723) Coplanarity…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.7.7 Changes to the Machine Data
5.7.7.1 Machine Data Converter
The machine data converter makes changes to the following machine files at level 75:
SIPLACE F
4
/ F
5
File Variable Description / Restriction
Konfig_L.ma Sensor system IDs/gantry group 0 Change for gantry group 1 (00723)
Coplanarity module removed
Konfig_r.ma Sensor system IDs/gantry group 0 Change for gantry group 1 (00723)
Coplanarity module removed
Kraft_12.ma Axis block 1:
In addition, 1 active value ID: 19
All force levels: 6th value, old 2047, new 80
Force level 13 (higher than 8x noz.): 2nd value, old 80, new 40
Force level 13 (higher than 8x noz.): 3rd value, old 18, new 0
Force level 13 (higher than 8x noz.): 4th and 5th value, old 250,
new 150
Force level 13 (higher than 8x noz.): 6th value, old 2047, new
20
Changed values for pick-up with
nozzles in 8-nozzle heads
PPW_STD.MA \ D-Sollposition \ jeweils 0 Nozzles wiped off at 0 degrees (00601)
REAL.MA Backlash time Backlash times changed (00603)
SCANPA06.MA New parameter values (00614)
SCANPA12.MA New parameter values (00614)
TRANSP.MA Center conveyor coasting and PCB
timeout configurable (00604)
ref_lauf.ma Default entry for adjustable retries for
the error: track empty (00605)
30 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
SIPLACE F5HM
File Variable Description / Restriction
KONFIG_L.MA Sensor system IDs/gantry group 0 Change to gantry group 1 (00723)
Coplanarity removed
KONFIG_R.MA Sensor system IDs/gantry group 0 Change to gantry group 1 (00723)
Coplanarity removed
PPW_STD.MA \ D-Sollposition \ jeweils 0 Nozzles wiped off at 0 degrees (00601)
SCANPA06.MA New parameter values (00614)
SCANPA12.MA New parameter values (00614)
TRANSP.MA Center conveyor coasting and PCB
timeout configurable (00604)
ref_lauf.ma Default entry for SpurleerMax (605)
scanpafc.ma New parameter values (00614)
31 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
SIPLACE S20
File Variable Description / Restriction
KRAFT_12.MA Axis block 1:
In addition, 1 active value ID: 19
All force levels: 6th value, old 2047, new 80
Force level 13 (higher than 8x noz.): 2nd value, old 80, new 40
Force level 13 (higher than 8x noz.): 3rd value, old 18, new 0
Force level 13 (higher than 8x noz.): 4th and 5th value, old 250,
new 150
Force level 13 (higher than 8x noz.): 6th value, old 2047, new
20
Changed values for pick-up with
nozzles in 8-nozzle heads
PPW_STD.MA \ D-Sollposition \ jeweils 0 Nozzles wiped off at 0 degrees
(00601)
REAL.MA Backlash times changed (00603)
SCANPA12.MA New parameter values (00614)
TRANSP.MA Center conveyor coasting and PCB
timeout configurable (00604)
ref_lauf.ma Default entry for adjustable retries
for the error: track empty (605)
SIPLACE S23
File Variable Description / Restriction
PPW_STD.MA \ D-Sollposition \ jeweils 0 Nozzles wiped off at 0 degrees
(00601)
REAL.MA Backlash times changed (00603)
SCANPA12.MA New parameter values (00614)
TRANSP.MA Center conveyor coasting and PCB
timeout configurable (00604)
ref_lauf.ma Default entry for adjustable retries
for the error: track empty (605)
32 of 104