00192231-09_VD_SSW 407.05_de en - 第36页

Software Version Description, Station Software Version 407.05 07/2008 Edition 5.8.9 Vacuum Evaluation and Vacuum Sequences (V3 Topics) The thresholds for vacuum evaluation (vakuum.ma) ar e no longer used as absolute valu…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
-
When tracks are refilled in the component level indicator dialog box, the container size is added to the
current component supply.
- A new container size can be entered manually in the "Supply and container" dialog box, or it can be
scanned in using the barcode reader. The track in question first has to be scanned using the barcode
reader, after which a barcode with an initial identifier and a following number must be read in. This
identifier can be set in the "Barcode ID Container size" function of the Main view -> Menu -> Settings ->
Configure GUI dialog. (Example: Setting QTY: Barcode QTY0002000: New container size 2000).
5.8.5 Feeder Position Recognition
Feeder position recognition is performed as soon as a new set-up is loaded and the set-up modification
generator has been confirmed. Feeders which are not recognized are displayed as track errors.
Feeder position recognition can be canceled or repeated.
All feeder fiducials are re-measured if feeder position recognition is repeated. A pick-up correction is only
performed for the recognized feeders in the event of a cancel.
5.8.6 Version Check
A version check between the machine controller and the station computer is performed when the machine is
started. If the versions are not the same:
a) an error message is output and
b) the machine does not continue its start-up (Æ additional installation required).
5.8.7 New "Multicolor" PCB Camera for F5HM
As of Version 407, it is possible to install the new "multicolor" PCB camera as an accessory on a SIPLACE
F5HM. The SIPLACE F5HM continues to be delivered with the old PCB camera.
The "multicolor" PCB camera is a flash camera and allows 4 different illumination settings.
5.8.8 Support for the 88 mm Tape Feeder
As of Version 407, the 88 mm tape feeder with line computer support can be set up on SIPLACE F
4
,
SIPLACE F
5
and SIPLACE F5HM machines. This requires the new table firmware B0V1030A.HEX, Version
003.10 (Tisch.hex), which is automatically installed on the machine controller when Version 407 is installed.
35 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.8.9 Vacuum Evaluation and Vacuum Sequences (V3 Topics)
The thresholds for vacuum evaluation (vakuum.ma) are no longer used as absolute values. The threshold is
calculated as a percentage of the vacuum values of the open and closed segment of each nozzle. This
means nozzle-related evaluation of the vacuum is achieved. Refer to the vacuum evaluation documentation
for more information.
5.8.10 ErrorLogger
To allow improved troubleshooting, the various error messages issued by the machine controller are passed
to the ErrorLogger. The log file thus created is evaluated using the Bugreporter and is used for further
problem analysis.
5.8.11 Head Reference Run
From version 407.01 onwards, the optimum position of the Z-axis in relation to the rocker is ascertained by a
second measurement. This considers the entry and exit of a segment from the rocker in the Z-axis (star axis
position +/- 2500 digits).
5.8.12 Top and Bottom PCB Barcode
To allow improved identification of the individual PCBs, Version 407.01 supports the PCB barcode on both
sides of the PCB. If two codes are read, the barcode on the top is always used for job monitoring. If a PCB
only has one barcode, the PCB can nevertheless be identified and components placed top and bottom.
The board is only assembled if, in the Barcode type allocation list on the line computer, the label side is
uniquely identified with "o" for the top the barcode or with "u" for the bottom the barcode. If "X" for no
information is entered, the board is passed through without being assembled.
36 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
5.8.13 fk_off.ma - Correction File for Fine Calibration
The correction values derived from the machine capability analysis and fine calibration used to be held in
real.ma. They have now been transferred to the file fk_off.ma. The entries for the relevant camera IDs and
transports are located in the file. The mean offsets from the machine capability analysis must be added to
the values in the "Global" data record depending on the feeder. (Important: These used to be subtracted in
real.ma!) The angle-dependent correction values from wnk_korr.ma (this file is removed) have also been
moved to the new file fk_off.ma. . The relevant offsets for the angles from fine calibration during the
assembly with IC head are added to the values in the records "0", "90", "180", "270", depending on the
conveyor.
Example:
\Dataset 1. BE-Camera \
\ CameraID \ 12#
\ KameraTyp \ "C&P12"#
\ Level \ 1#
\ Number of sets \ 1#
\ 1. Correction Set \
\ ID-Name \ "GLOBAL";
\ 1. Transport \
\X-Offset in microns \ 8,
\Y-Offset in microns \ -9,
\W-Offset in 1/100 degree \ 1!
Adding the global
offsets
depending on
the conveyor in which
the measuring plate
was placed.
\ 2. Transport \
\X-Offset in microns \ -7,
\Y-Offset in microns \ 13,
\W-Offset in 1/100 degree \ -2!
5.8.14 Improvements in the SITEST Test and Commissioning Program
5.8.14.1 Illumination Values for Live Images in SITEST
The illumination values for various illumination levels can be set for the new "Multicolor" PCB camera for the
live image, in order to test the illumination.
This button is inactive for the old PCB camera!
5.8.14.2 Accelerated calibration of the 12-segment C&P head
Measurement of segment offset I and segment offset II is now only repeated 4x for 12-segment heads.
For reasons of accuracy, the measurement is repeated 8x for 6-segment heads.
37 of 104