00192231-09_VD_SSW 407.05_de en - 第39页
Software Version Description, Station Software Version 407.05 07/2008 Edition 6 Error Corrections 6.1 Errors Corrected in the 407.05 Sof tware 1-9MYGD On an F5HM machine an error concerning the segments 2-5 often occur…

Software Version Description, Station Software Version 407.05 07/2008 Edition
5.8.14.3 Rapid head mapping
C&P and IC head mapping is now carried out with only one calibration tool package form instead of 4.
For this reason, the calibration tool package form is picked up off center.
5.8.15 Changes to the Machine Data
5.8.15.1 Machine Data Converter
The machine data converter makes changes to the following machine files at level 70:
File Variable Description / Restriction
Height offsets Read global offset values and make entry in FK_OFF.MA
Then reset Height Offsets to zero.
REAL.MA
Backlash time Set backlash time of the C&P camera to 50 ms
Restriction: only 6-nozzle heads with standard or DCA
cameras.
WNK_KORR.MA
Angle correction values Read correction values and make entry in FK_OFF.MA
WNK_KORR.MA is then deleted by the installation procedure.
Vacuum threshold, pickup/place Set to 30% for all heads.
VAKUUM.MA
Number of errors per segment Set number of errors per segment from 3 to 10.
Restriction: For 12-nozzle heads only
FK_OFF.MA
New file Values from REAL.MA are transferred in inverted form.
Correction values from WNK_KORR.MA are transferred.
TRANSP.MA
Input conveyor sensor timeout Introduce input conveyor sensor timeout [s] for both conveyor
tracks and set to 8 s.
The following values are changed during installation of the MC software.
File Variable Description / Restriction
KALI_GF.*
KALI_MB.*
Files from the directory D:\Dat (MC) are used from C:\
SRDaten \ SrcSiTest .. (SC) as of Version 407.
VAK_Z.MA
Nozzle type 902 added
VAKUUM.MA
Evaluation of minimum vacuum
distance
Changed data format
ACHS12MF.MA
ACHS12OF.MA
ACHS6MF.MA
ACHS6OF.MA
AX12STD.MA
AX6STD.MA
Values for forces, acceleration and positions changed.
38 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
6 Error Corrections
6.1 Errors Corrected in the 407.05 Software
1-9MYGD
On an F5HM machine an error concerning the segments 2-5 often occurred for the 6 nozzle head
(segment untight after placement). The software for the axes has been adapted
1-DTQP0
The reference run of the C&P head did not work, because some segments were empty. Empty
segments will not be regarded during heights reference run anymore.
1-CO0XG
During placement of a high component from a tray (last component of the PCB) a track error occurred,
but the level did not turn back into the tower as the PCB was finished.
If a component then was picked up from a tray for the next PCB, the level with the high component was
still activated, since the SP head was reactivated when a track or a tray was filled up with components.
This reactivation is not performed by filling up anymore.
1-COMI5
After placing high components on an F
4
machine, an empty segment of the 12-nozzle head was not
moved down during parking. The function has been adapted.
1-GE58V
OIS did not document component rejects correctly, since an error message was not forwarded to OIS.
The error log file has been adapted accordingly.
1-GEXBA
By rebooting a SIPLACE S20 machine, the error message "konfig.ma file missing or faulty" was
displayed. This was caused by timing problems during access on the konfig.ma file. The access method
has been modified.
752-4SF
On an F
5
machine, the entries for 2 feeder tracks were missing in the Component Level Indicator (CLI)
on the station GUI. The error has been corrected.
D1-34579101
It was impossible to activate a reel and BCSupplier.exe registered a problem. The error has been
corrected.
D1-34855617
Conveyor error as PCB was transferred between an HS50 and an F4 machine. The error has been
corrected.
39 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
D1-39368211
Error on an F5HM machine with IC head, when a placement force of 15N was preset for a component.
However, the maximum placement force for the IC head is 10N. The placement force has been
restricted accordingly.
D1-39569410
After a machine reboot, the level indicator window was provided with data. By exiting the menu and
restarting it, the window was empty. The data did not appear again until the machine was rebooted. The
components for setup data supply and display have been adapted.
D1-39654613
After upgrading to station software 407.04SP2 on a SIPLACE F
5
machine, no connection could be
established between SIPLACE Pro and the station, since the maximal number of 100 different nozzle
types was exceeded. The maximal number of different nozzle types has been increased to 200.
D1-39859001
After a job change, the tracks had to be rescanned after the tables were scanned (firm setup) to start
production. The interface between station and Setup Center has been adapted.
D10911-4847
An S20 machine hung up with the error message 2439 (error in placement sequence software). The
placement sequence has been optimized.
D11991-3507
Wrong fiducial coordinates in the fine calibration on an S23 machine. The fiducial coordinates have been
modified.
D12014-2209
A data preparation error occurred due to the package form, but it was difficult to identify the cause. The
error messages have been improved and now additionally report the fiducial or shape number that is
currently in process.
6.2 Errors Corrected in the 407.04 Servicepack 2 Software
• 1-H33G5
Problems on the F5 machine. Error on the panel.
The maximum number of nozzles in the nozzle record was increased on the panel.
• 1-J3CIT
The following error message is displayed "2405 Konfig.ma file missing or faulty".
40 of 104