1-9MYGD
On an F5HM machine an error concerning the segments 2-5 often occurred for the 6 nozzle head
(segment untight after placement). The software for the axes has been adapted
1-DTQP0
The reference run of the C&P head did not work, because some segments were empty. Empty
segments will not be regarded during heights reference run anymore.
1-CO0XG
During placement of a high component from a tray (last component of the PCB) a track error occurred,
but the level did not turn back into the tower as the PCB was finished.
If a component then was picked up from a tray for the next PCB, the level with the high component was
still activated, since the SP head was reactivated when a track or a tray was filled up with components.
This reactivation is not performed by filling up anymore.
1-COMI5
After placing high components on an F
4
machine, an empty segment of the 12-nozzle head was not
moved down during parking. The function has been adapted.
1-GE58V
OIS did not document component rejects correctly, since an error message was not forwarded to OIS.
The error log file has been adapted accordingly.
1-GEXBA
By rebooting a SIPLACE S20 machine, the error message "konfig.ma file missing or faulty" was
displayed. This was caused by timing problems during access on the konfig.ma file. The access method
has been modified.
752-4SF
On an F
5
machine, the entries for 2 feeder tracks were missing in the Component Level Indicator (CLI)
on the station GUI. The error has been corrected.
D1-34579101
It was impossible to activate a reel and BCSupplier.exe registered a problem. The error has been
corrected.
D1-34855617
Conveyor error as PCB was transferred between an HS50 and an F4 machine. The error has been
corrected.
39 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
D1-39368211
Error on an F5HM machine with IC head, when a placement force of 15N was preset for a component.
However, the maximum placement force for the IC head is 10N. The placement force has been
restricted accordingly.
D1-39569410
After a machine reboot, the level indicator window was provided with data. By exiting the menu and
restarting it, the window was empty. The data did not appear again until the machine was rebooted. The
components for setup data supply and display have been adapted.
D1-39654613
After upgrading to station software 407.04SP2 on a SIPLACE F
5
machine, no connection could be
established between SIPLACE Pro and the station, since the maximal number of 100 different nozzle
types was exceeded. The maximal number of different nozzle types has been increased to 200.
D1-39859001
After a job change, the tracks had to be rescanned after the tables were scanned (firm setup) to start
production. The interface between station and Setup Center has been adapted.
D10911-4847
An S20 machine hung up with the error message 2439 (error in placement sequence software). The
placement sequence has been optimized.
D11991-3507
Wrong fiducial coordinates in the fine calibration on an S23 machine. The fiducial coordinates have been
modified.
D12014-2209
A data preparation error occurred due to the package form, but it was difficult to identify the cause. The
error messages have been improved and now additionally report the fiducial or shape number that is
currently in process.
6.2 Errors Corrected in the 407.04 Servicepack 2 Software
• 1-H33G5
Problems on the F5 machine. Error on the panel.
The maximum number of nozzles in the nozzle record was increased on the panel.
• 1-J3CIT
The following error message is displayed "2405 Konfig.ma file missing or faulty".
40 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
6.3 Errors Corrected in the 407.04 Servicepack 1 Software Patch C
• 1-BLJV9
The option for nozzle splitting has to be activated at first.
• 1-GITMI
If the C&P head is not occupied completely, the data of the xml file is not transmitted correctly. The error
has been corrected and the data is transmitted correctly.
• 1-COMI5
Problems with high components. The error has been corrected.
• 1-GYJ67
The component level indicator hangs up when upgrading. The component level indictor has been
reengineered.
• 1-GEMPS
Error 44 post vision
An error message is displayed, if no component is on the nozzle before placement.
6.4 Errors Corrected in the 407.04 Servicepack 1 Software
• The tracks cannot be sorted by the buffer time (FM 1- AEAM5)
The tracks cannot be sorted by the buffer time in the component level indicator. This error has been
corrected in this version.
• Tracks which fall below the threshold are not deactivated (FM 1-B8QOH)
When the operator opens the component level indicator menu, tracks which have fallen below the
threshold are not deactivated. The error has been corrected.
• Log manual entry of barcode (FM 1–BKNID)
Manual entry of the PCB barcode is now documented in a separate error code in the XML file.
• Suppress manual entry of the PCB barcode by a configuration mechanism (FM 1-BKNRF)
A configuration option has been added to the user interface for service engineers to disable manual
entry of the PCB barcode.
• Missing barcode verification: tracks deactivated even though the filling levels are displayed
correctly. (FM 1-BQY2X)
Tracks are not released (missing barcode verification: tracks deactivated) even though the filling levels
are displayed correctly. The error has been corrected.
• Operator ID is not written to the traceability file. (FM 1-CIYKH)
According to the version description, the operator ID must be written to the trace files. The error has