Software Version Description, Station Software Version 407.05 07/2008 Edition 6.3 Errors Corrected in the 407.04 Servicep ack 1 Sof tware Patch C • 1-BLJV9 The option for nozzle splitting has to be activated at first. • …
Software Version Description, Station Software Version 407.05 07/2008 Edition
D1-39368211
Error on an F5HM machine with IC head, when a placement force of 15N was preset for a component.
However, the maximum placement force for the IC head is 10N. The placement force has been
restricted accordingly.
D1-39569410
After a machine reboot, the level indicator window was provided with data. By exiting the menu and
restarting it, the window was empty. The data did not appear again until the machine was rebooted. The
components for setup data supply and display have been adapted.
D1-39654613
After upgrading to station software 407.04SP2 on a SIPLACE F
5
machine, no connection could be
established between SIPLACE Pro and the station, since the maximal number of 100 different nozzle
types was exceeded. The maximal number of different nozzle types has been increased to 200.
D1-39859001
After a job change, the tracks had to be rescanned after the tables were scanned (firm setup) to start
production. The interface between station and Setup Center has been adapted.
D10911-4847
An S20 machine hung up with the error message 2439 (error in placement sequence software). The
placement sequence has been optimized.
D11991-3507
Wrong fiducial coordinates in the fine calibration on an S23 machine. The fiducial coordinates have been
modified.
D12014-2209
A data preparation error occurred due to the package form, but it was difficult to identify the cause. The
error messages have been improved and now additionally report the fiducial or shape number that is
currently in process.
6.2 Errors Corrected in the 407.04 Servicepack 2 Software
• 1-H33G5
Problems on the F5 machine. Error on the panel.
The maximum number of nozzles in the nozzle record was increased on the panel.
• 1-J3CIT
The following error message is displayed "2405 Konfig.ma file missing or faulty".
40 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
6.3 Errors Corrected in the 407.04 Servicepack 1 Software Patch C
• 1-BLJV9
The option for nozzle splitting has to be activated at first.
• 1-GITMI
If the C&P head is not occupied completely, the data of the xml file is not transmitted correctly. The error
has been corrected and the data is transmitted correctly.
• 1-COMI5
Problems with high components. The error has been corrected.
• 1-GYJ67
The component level indicator hangs up when upgrading. The component level indictor has been
reengineered.
• 1-GEMPS
Error 44 post vision
An error message is displayed, if no component is on the nozzle before placement.
6.4 Errors Corrected in the 407.04 Servicepack 1 Software
• The tracks cannot be sorted by the buffer time (FM 1- AEAM5)
The tracks cannot be sorted by the buffer time in the component level indicator. This error has been
corrected in this version.
• Tracks which fall below the threshold are not deactivated (FM 1-B8QOH)
When the operator opens the component level indicator menu, tracks which have fallen below the
threshold are not deactivated. The error has been corrected.
• Log manual entry of barcode (FM 1–BKNID)
Manual entry of the PCB barcode is now documented in a separate error code in the XML file.
• Suppress manual entry of the PCB barcode by a configuration mechanism (FM 1-BKNRF)
A configuration option has been added to the user interface for service engineers to disable manual
entry of the PCB barcode.
• Missing barcode verification: tracks deactivated even though the filling levels are displayed
correctly. (FM 1-BQY2X)
Tracks are not released (missing barcode verification: tracks deactivated) even though the filling levels
are displayed correctly. The error has been corrected.
• Operator ID is not written to the traceability file. (FM 1-CIYKH)
According to the version description, the operator ID must be written to the trace files. The error has
been corrected.
41 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
• The XML file is not generated in the traceability feature. The file is always in *.tmp. (FM 1-CO5U5)
The system cannot convert *.tmp files to XML. The XML file is not generated. The error has been
corrected.
• Fine calibration is not possible with Stations software 407.04 and IC head (FM 1-CTK0G)
The fiducials are not centered correctly with IC head. The fiducials are not recognized correctly and the
fine calibration aborts. The error has been corrected.
• The level indicator on the station computer causes a system crash. (FM 1-CN4F9)
The error has been corrected.
• SIPLACE Pro LC GUI is unable to connect to Station S20 (FM 1-DCHJC)
After new installation of Win XP SP2 and the stations software 407.04 there was no LC GUI connection
to Station S20. The error has been corrected.
• In barcode mode the component level indicator hangs up (FM 5LZ-2S9)
The error has been corrected.
6.5 Errors Corrected in the 407.04 Software
• Error report 1-47755
Occasionally, the message "Leak in segment after placement" was displayed for MC1 instead of MC2.
This meant that attempts to isolate the problem were made on the wrong hardware component. This
error has been corrected in this version.
• Error report 1-4JS09
If an error occurs when measuring components, several messages can be issued. This is necessary in
order to trace the cause of the error. These individual errors were previously also reported to OIS. This
caused the number of components consumed to be calculated incorrectly.
The report to OIS has been corrected.
• Error report 1-6LWNT
The touch screen is not installed automatically when the 407.02 station computer software is installed.
Windows NT 4.0 for the N300, P300 had previously been installed on the computer. The touch screen
driver then has to be installed manually from the CD. The installation routine has been adjusted.
• Error report 1-6YNDP
Error in measurement procedure for WPC fiducial recognition Measurement is carried out for every
board. The fiducials cannot be measured correctly (they are not recognized correctly or they are not
centered correctly). This causes the pickup position of the WPC to be incorrect and the correction
values have to be adjusted on the line computer. The measurement procedures have been reworked.
Pickup correction is now calculated correctly.