Software Version Description, Station Software Version 407.05 07/2008 Edition
The XML file is not generated in the traceability feature. The file is always in *.tmp. (FM 1-CO5U5)
The system cannot convert *.tmp files to XML. The XML file is not generated. The error has been
corrected.
Fine calibration is not possible with Stations software 407.04 and IC head (FM 1-CTK0G)
The fiducials are not centered correctly with IC head. The fiducials are not recognized correctly and the
fine calibration aborts. The error has been corrected.
The level indicator on the station computer causes a system crash. (FM 1-CN4F9)
The error has been corrected.
SIPLACE Pro LC GUI is unable to connect to Station S20 (FM 1-DCHJC)
After new installation of Win XP SP2 and the stations software 407.04 there was no LC GUI connection
to Station S20. The error has been corrected.
In barcode mode the component level indicator hangs up (FM 5LZ-2S9)
The error has been corrected.
6.5 Errors Corrected in the 407.04 Software
Error report 1-47755
Occasionally, the message "Leak in segment after placement" was displayed for MC1 instead of MC2.
This meant that attempts to isolate the problem were made on the wrong hardware component. This
error has been corrected in this version.
Error report 1-4JS09
If an error occurs when measuring components, several messages can be issued. This is necessary in
order to trace the cause of the error. These individual errors were previously also reported to OIS. This
caused the number of components consumed to be calculated incorrectly.
The report to OIS has been corrected.
Error report 1-6LWNT
The touch screen is not installed automatically when the 407.02 station computer software is installed.
Windows NT 4.0 for the N300, P300 had previously been installed on the computer. The touch screen
driver then has to be installed manually from the CD. The installation routine has been adjusted.
Error report 1-6YNDP
Error in measurement procedure for WPC fiducial recognition Measurement is carried out for every
board. The fiducials cannot be measured correctly (they are not recognized correctly or they are not
centered correctly). This causes the pickup position of the WPC to be incorrect and the correction
values have to be adjusted on the line computer. The measurement procedures have been reworked.
Pickup correction is now calculated correctly.
42 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
Error report 1-7SEIY
Software error in the integrated SOKO "high components" on SIPLACE F5HM machines.
After high components have been placed on a board in conveyor 1 (asynchronous dual conveyor), the
gantry moves to the fiducial of the board in conveyor 2 while the star is turning and in the process
removes the high components that have already been placed. The procedure has been improved.
Error report 1-84JSH
The fine calibration programs in version 407.02 contained an incorrect fiducial position. Furthermore,
720 / 920 nozzles were on the C&P12 heads while only the IC head was placing components.
The programs have been reworked
Error report 1-7WXPW
If an S20 is upgraded from 407.02 SP1 to 407.03, the machine data converter aborts with the message
"not successful". The log file indicates that conversion was not successful for the following 5 files:
- Achs.ma
- Achs_std.ma
- Mappsteu.ma
- Kraft.ma
- Scanpara.ma
The converter was modified accordingly.
Error report 1-8RN1H
When switching between various placement programs, the error message "2477 Unknown nozzle at
segment, none specified in configuration" was issued. The cause of this was that the currently measured
nozzle lengths were not initialized during the height reference run.
Error report 1-8S0H9
Problems on picking up components from very deep pockets. The feeder is moves on before the nozzle
has left the component pocket. As a result, the nozzle is trapped in the feeder and the gantry axes start
to move. This damages the IC head. This error was eliminated by revising the cycle sequence.
Error report 1-8S719
User interface crashes. Machine must be rebooted.
Problems representing the individual component levels occurred in the context of the component level
indicator. If the data was updated and at the same time the user clicked on the surrounding interface,
incorrect data accesses occurred and the interface crashed. It was possible to eliminate the cause of
this error.
Error report 1-8VMHY
In the software version description version 4.01 is still stated as a requirement for SIPLACE S23 and
SIPLACE F5HM. This is not correct. Version 4.03 of the firmware should be read in.
43 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
Error report 1UA-6EO
In unfavorable circumstances, it is possible that components are placed twice on a board. The
components are then stacked on top of each other. It was possible to eliminate the cause of this error.
Error report 3RS-2N3 and error report 1-8VMHD
If a nozzle error occurs on the machine, the incorrect MC is shown at the GUI. Also, segment 13 is
displayed. The displayed segment was calculated incorrectly.
The calculation has been corrected and now the correct segment is displayed on a nozzle error.
6.6 Errors Corrected in the 407.03 Software
Error report 1-5WP6D
When individual calibration or axis functions on the Z axis are called up, it is no longer possible to move
without a sleeve. After the reference run, the star is no longer moved into its parked position in SITEST.
Error report 1-38UHD & error report 1-4X3EQ
On a SIPLACE machine with 407.02 software, if the STOP key was pressed and then the covers were
opened, the axes remained switched on (ON lamp lit on the axis card).
The axis was only released by pressing the EMERGENCY STOP button. This behavior has been
corrected. The axes are now deactivated as soon as the cover is opened.
Error report 1-4NW2M
"Error in placement sequence software" appears when the job is specified. The station still accepts the
job and only places with one gantry even though both gantries should be placing.
This was caused by an error correction for position recognition that was not performed correctly. It
meant that the second gantry never received permission to place.
Error report 1-4AZS9
When a new program is specified, nozzle 418 is always on the IC head in the software. The nozzle must
always be attached manually otherwise problems occur when the nozzle is changed.
The calibration of the set-up (feeder position recognition and nozzle configuration) was not observed by
the MC. Thus the problem described above occurred.
Error report 1-55UQP
If a fiducial is taught with a multicolor camera on a SIPLACE F5HM machine, irrespective of whether it is
synthetic or 2D, the illumination color selection does not match the actual illumination.
Two illumination levels were confused when the hardware was controlled. In Version 407.03, the correct
levels are controlled.
Error report 1-2HH89
In connection with the dip fluxing option, it was possible under unfavorable conditions that a component
would not be placed. This error only occurred on head cycles that did not have components on all
segments and one of these components had to be dipped.
44 of 104