00192231-09_VD_SSW 407.05_de en - 第47页

Software Version Description, Station Software Version 407.05 07/2008 Edition • At installation of the SIPLACE F5HM, the int egrated C&P head can be selected. Consequently, when the machine is restarted, no error occ…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
Error report 1-4U47O
The old mapping fiducial is still installed in Version 407.02. A reworked fiducial has been adopted from
Version 503.
Error report 1-62Z6H
In Version 407.02, the directory "C:\SRDaten\Target" fills up completely on the station computer during
long uninterrupted operation of the SIPLACE machines. The problem only occurs in conjunction with the
PCB barcode and very small recipe sizes. When the SIPLACE machines are started, all temporary files
in this directory are now deleted.
Error report 1-6SXU7
When Version 407.03 is installed, it checks whether OIS has already been installed. If this is the case,
no change is made in the Registry. Otherwise, the value required for the software is generated in the
Registry.
6.7 Errors Corrected in the 407.02 Software Service Pack 1
Error report 1-497W9
In the menu for teaching synthetic fiducials, it is not possible to move to a fiducial by clicking with the
mouse in the submenu "Teach synthetic fiducial" – "Gantry positioning". The error message "Target
position outside travel range" appears.
Error report 1-4BXFD
The table for individual illumination settings can no longer be used for teaching package forms with
station software Version 407.02. The illumination values are displayed inverted when the dialog box is
exited.
6.8 Errors Corrected in the 407.02a Software
The patch provides more reliable detection of calibration tool fiducials (fiducial 252). However, it doubles
the time taken to measure each individual calibration fiducial. It does not increase the time taken to
measure other fiducials and ink spots.
6.9 Errors Corrected in the 407.02 Software
For feeder position recognition and set-up checking with barcodes, the settings (active/inactive) are
stored in the registry. Consequently, these options do not have to be set again every time the SIPLACE
machines are switched on.
The accuracy of time recording for the OIS has been improved. For all information to the OIS the time is
given to an accuracy of 1/1000 second. This allows messages that occur within the same second to be
displayed better.
46 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
At installation of the SIPLACE F5HM, the integrated C&P head can be selected. Consequently, when the
machine is restarted, no error occurs during data preparation.
The set-up positions of the machines have been moved by 70 mm. This permits free access to the
nozzle changers.
The configuration of ceramic substrate centering for the "Multicolor" PCB camera in the SIPLACE F5HM
has been changed. It is no longer possible to select oblique illumination.
The "Stop processing PCB" button no longer has to be used in fine calibration during the placement
process. The printed circuit board remains on the center conveyor automatically.
Error report 1-YZ9D
Dip fluxing is possible with the IC head on the SIPLACE F
4
and the SIPLACE F5HM with the 12-nozzle
C&P head as of version 407.02.
Note: If components are set up that can be placed with either the 12-nozzle C&P head or the IC head, it
can happen that they are placed by the C&P head. These are then without additional solder paste. Dip
fluxing is still not supported for the 12-nozzle C&P head.
Error report 123950
Following the installation of the station software, the A0110401.hex file (axis firmware version 4.001) is
located on the machine's station computer.
It can be copied to floppy disk from the "C:\SRProgramme\AchsFW\" directory.
1-3DP3M:
SIPLACE Pro interface: If a job was specified again with automatic width adjustment activated after
component package forms were taught, the conveyor width was measured again.
This is not necessary at this point, however, and is now no longer done.
1-3DYCT:
SIPLACE Pro interface: If a job was specified again after component package forms were taught, the job
for conveyor 1 was missing. This has been changed.
1-3CGHX:
SIPLACE Pro interface: If a job was specified again after the execution of the package form manipulator,
the preceding job was then processed rather than this job. The correct job is now processed.
1-2DM76
General problem when picking up heavy components in conjunction with 72x nozzles. The parameters in
the "Kraft.ma" file are modified for the 12-nozzle C&P heads of the SIPLACE S20 and SIPLACE F
4
( ).
This ensures that heavy components are also picked up and placed reliably.
Error report 120454
When the PCB reference corners were taught, the C&P head position was displayed on the GUI rather
than the PCB camera position. The PCB reference corner position is now displayed correctly in SITEST.
Error report 120714
47 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
The message "Action: Waiting till output conveyor empty" was not displayed after a fiducial had been
taught (and saved). This error occurred whenever the PCB could not move from the processing area to
the output conveyor (because the latter was occupied by another PCB). The station came to a standstill
without displaying a message indicating the error. The hourglass displayed on the monitor would not go
away, indicating an incomplete process. For this reason, the necessary status displays have been
permitted for the conveyor in set-up mode.
Error report 120826
When there is a drop in pressure during placement, the SIPLACE machine comes to a standstill, and the
error message "No compressed air" is displayed. As soon as the compressed air returns, placement can
be resumed after the start button is pressed. The fitted printed circuit board was then occasionally
passed on to the next machine although components may have been missing. The software has been
modified so that the affected printed circuit board is now stopped on the output conveyor in the
processing area, allowing a check to be carried out (notification window).
Error report 121770
If a nozzle was removed from the C&P head of a SIPLACE machine (except for an S15/F3) and then
picked up again immediately, a pick-up error occasionally occurred. The sleeve attempted to pick up a
nozzle from the 12- or 6-nozzle changer with the rotational axis turned by 90°. The error has been
corrected by a change to the "PPW_STD.MA" machine file.
Error report 123103
In C&P mapping, the clamping was not released on conveyor 2 on completion of the mapping run. The
error has been corrected.
Error report 123742
The container size was not scanned in by the barcode reader when the level monitoring option was set.
In order to correct this error, a change from version 502.01 has been adopted.
Error report 123796
After the PCB camera was replaced, it could not be calibrated because incorrect calibration factors were
entered for bx and by. The calibration factors are now entered correctly when the PCB camera is
reconfigured.
Error report 123813
When the height of the IC nozzle changer was calibrated, a superfluous height check was carried out.
This occasionally caused calibration to function incorrectly. The unnecessary height check has been
eliminated.
Error report 123869
In the "Teach PCB camera" menu (gantry, PCB camera functions) in SITEST, the wrong illumination
was switched on (blue selected, but white switched on). This has been corrected.
Error report 123901
Components were sometimes placed on the PCBs even when the PCB clamp was not working. No error
message appeared. The transport software now checks both Bero proximity switches when clamping a
PCB. As a result, this error is avoided.
48 of 104