00192231-09_VD_SSW 407.05_de en - 第50页

Software Version Description, Station Software Version 407.05 07/2008 Edition 6.10 Errors Corrected in Service Pack 2 of the 407.01 Sof t ware • Error report 123474 The output conveyor interface did not function as speci…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
Error report 123390
In the vacuum test, the vacuum value measured was compared with the threshold "min. Vakuumwert
Segment zu" (minimum vacuum value with the segment closed) from the "Vakuum.ma" machine file. If
the closed value was under this threshold, the following error message appeared erroneously: "2277
The difference between open and closed vacuum values is too small." In version 407.02, the error
message "2455 Vacuum value of segment too low with valve closed" is issued.
Error report 1-1MLCH
Incorrect parameter values in the "scanpara.ma" machine file. The values have been taken from the
technical information (ref. no. 10V05020).
Error report 1-1IHCG and Error report DH-E
High pick-up error rate (around every 3rd head cycle for segment 7) when special sequences were
programmed for the gantries. It sometimes happened that the hand of the feeder had closed before the
component could be picked up. The timing of the sequences has been optimized. This prevents the
hand of the feeder from being retracted and closing again too early before the Z-axis can move down.
Error report 1-2HH89
When the dip fluxing option was used, it occasionally happened that a component was not placed. This
error has been corrected in version 407.02.
Error report 123965
In the default machine data of version 407.01, a "Ratio -IC- Sensor" camera is now entered as the
default for a SIPLACE F
4
instead of the old IC camera. This camera replaced the old standard camera
and was then used in all new machines. The old camera therefore has to be configured in SITEST after
a new installation or reinstallation of SIPLACE.
Error report 120743
When the camera position was displayed (calibration of the IC head and camera in the "Calibrate entire
machine" menu), the current and old values were the same. The values are now displayed correctly.
Error report 123953
If you install the 407.01 software on the station computer, you can also enter the addresses for the
SIPLACE LAN via the installation menu. You cannot change the machine's IP addresses in this dialog
box. The addresses entered must agree with NT or RMOS. If you want to change the IP addresses, call
the Siemens Hotline.
49 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
6.10 Errors Corrected in Service Pack 2 of the 407.01 Software
Error report 123474
The output conveyor interface did not function as specified. With downstream transport modules it
sometimes happened that a printed circuit board continued to be transported from the output
conveyor although no release had been issued. The software has been adapted accordingly.
Error report 123859
Problems with the measurement of a QFP100 have been removed by FW 308 of the coplanarity
module.
Error report 123840
Correction of an error in data preparation for coplanarity measurement. When a number of
components were to be measured with coplanarity, errors occurred when the component moved
over the coplanarity module.
Error report 1-1EJ7P
If a triple feeder for 0201 components was placed on a SIPLACE F5HM (407.01 software, SP1),
only track 1 of the feeder was stepped forward to the pick-up position, although, when a component
was set up on track 2, the station moved to this position and attempted to pick up components. The
same error occurred when a component was set up on track 3 of the above feeder. The error has
been corrected in Service Pack 2.
Error report 17F-M
Individual balls of a BGA were displayed badly displaced on the ICOS screen. The error could occur
with BGAs that were larger than 32.5 mm and not completely covered with balls.
For fine calibration with the IC head, no values were displayed for the four angular groups for
machines with a 12-nozzle head.
Error report 123460
In the case of DLM1 heads, customers frequently complained of distorted raceways. The reasons
for this are the transition between the raceway and the Z-claw and incorrect zero point correction of
the Z-axis. In order to remove the problem for platform 1 machines as well, the solution was taken
from version 502.01 SP3.
Error report 1-2M5Z5
When the first PCB moved into the first SIPLACE machine after a lengthy waiting time (synchr. dual
conveyor), it sometimes happened that the input conveyor did not respond correctly to this PCB.
The problem has been analyzed and corrected.
Error report 1-1ZQA1
Problems when the PCB barcode was requested frequently. A timeout error often occurred when
the barcode was read.
50 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
6.11 Errors Corrected in Software 407.01 Servicepack 1
Error report 123755
Sporadic message (actionline) "Switch on compressed air":
This message appears as a result of modifications to the electric compressed air valve.
The software has been corrected accordingly.
Error report 123746
Diagnostics not installed (data similar to 406):
The data for version 407.01 is installed by the service pack.
Adaptation of the BDELR process as a result of sporadic crashes. This has meant that the line computer
could not be supplied with data for MaDaMaS. A further effect of this was a slowing of all the production
processes on the affected machine.
It is not possible to change language several times in SITEST tool in version 407.01. The cause of the
error has been eliminated. This means that the language can be changed in the usual manner.
Using the pf-File (20_5.gf) for the calibrating-part to the calibrate the PCB camera from the version 502.
The fine calibration for the 12-segment C&P head is carried out using ceramic pads.
6.12 Errors Corrected in Software 407.01
Error message "2278 IC: interval open - closed vacuum value too low" when using gripper nozzles.
Up to now, a change had to be carried out at the line computer in order to use gripper nozzles
(modification to the ".kd" file on the line computer). As of version 407, the gripper nozzle has been
implemented correctly in the MC software and the modification to the ".kd" file must be reversed (this
has already been done if an update to the line computer software version 502.xx has been carried out).
"2255 Axis error: Command DAIN, but bit set"
Corrected by modification to the axis driver.
Error report – ID 1999.10/EA1E/0089 (205)
Width adjustment error no longer requires Start button to be pressed. Instead, it switches directly to set-
up mode. Here it is possible to correct the error in the conveyor controller or using SITEST. The
procedure is terminated with the "Continue processing" button
It is no longer possible for the station to "hang" after SITEST is run as it was in Version 406.01.
Error report – ID 1999.11/EAEENG/0006 (140366)
Check the position of the axes in the event that a retracted sleeve is mounted.
51 of 104