Software Version Description, Station Software Version 407.05 07/2008 Edition 7.1.10 Miscellaneous • Conveyor mode 2 (PCBs longer than 508 mm) is not supported. • Fine calibration cannot be carried out when ceramic subst…

100%1 / 208
Software Version Description, Station Software Version 407.05 07/2008 Edition
7.1.7 "High Components" Special Design
This special feature can only be used on the last machine in a line.
The machine's placement performance is reduced.
The special design cannot work together with multicolor cameras because the camera is too high.
Adherence to the placement sequence is required. No more lower components can be placed after
placement of high components.
In the case of very low components, it is possible that the C&P head can no longer pick up the
components. It is possible to do something here, however: You can put a base under the magazines.
In order to obtain the maximum height clearance, a special sleeve must be set up by hand in the first
segment on the 6-nozzle C&P head.
The placed board must not be aborted if there is a machine error. Otherwise, the head will turn the star
over the placement positions of the high components and clear the board.
7.1.8 Component level indicator
The display of the boards which can be fit with the current component configuration is only valid, when the
first board of a panel is finished.
7.1.9 Traceability
The threshold value "Remaining length in mm" may only be activated when the traceability option is
installed.
The PCB barcodes of all the boards in the machine must be different. If boards with identical barcodes
are in the machine, it is no longer possible to guarantee the accuracy of the traceability data.
Make sure that all stations are switched on during component verification. If this is not done, some of the
recorded information is lost and must be re-scanned after the machine has been switched on.
In the XML file (as of Version 1.1 or 2.1) on platform 2, information is logged as to whether a subpanel
was assembled or inked out (omit = TRUE / FALSE). Because the programming system does not
provide the required data, this cannot be output for Version 407.04.SP1.
Operation of traceability is not possible in conjunction with PCB barcode mode.
57 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
7.1.10 Miscellaneous
Conveyor mode 2 (PCBs longer than 508 mm) is not supported.
Fine calibration cannot be carried out when ceramic substrate centering is installed. There is a risk of
damaging the conveyor when inserting the light table.
Feeder position recognition is only possible for track 115 to a limited extent, because the relevant gantry
cannot move to the feeder fiducial for track 115.
The reference designator is transferred to GEM with a length of only 21 characters.
58 of 104
Software Version Description, Station Software Version 407.05 07/2008 Edition
8 Enclosures
None