00196376-0102_UM S-Feeder_EN - 第48页

Tape Feeder Modules Details for 24/32, 44, 56, 72 and 88 mm S or S DP Converting the Tape Width for 24/32 mm S Feeders 48 User Manual SIPLACE S-Feeder 2.4 Details for 24/32, 44, 56, 72 and 88 mm S or S DP 2.4.1 Convertin…

100%1 / 106
Tape Feeder Modules
Setting the Step Size Details for 12/16 mm S
User Manual SIPLACE S-Feeder 47
2.3.3 Setting the Step Size
To set the step size, proceed as follows:
(1) Press the green "Index" button and hold until the LED display begins to flash. Continue to hold the
button pressed.
(2) Press the yellow "Foil" button several times until the control unit display shows the required step
size in mm. The step size is increased by 4 mm each time you press the button.
If you accidentally exceed the required size, you can correct the setting using one of the following
options:
Press the yellow "Foil" button frequently, until the required step size is shown in the control unit
display.
Alternatively:
While you are in setting mode (display flashes), you can let go of the button and then press the
green button again (within one second) to reverse the direction of counting. The step size will
now be reduced by 4 mm each time you press the button.
You can reverse the direction of counting as often as you wish.
Release both buttons.
The setting procedure is finished when the flashing display changes to a permanent display.
For an overview of the available step sizes, refer to "1.3 Technical Data" [ ➙ 10].
Tape Feeder Modules
Details for 24/32, 44, 56, 72 and 88 mm S or S DP Converting the Tape Width for 24/32 mm S Feeders
48 User Manual SIPLACE S-Feeder
2.4 Details for 24/32, 44, 56, 72 and 88 mm S or S DP
2.4.1 Converting the Tape Width for 24/32 mm S Feeders
To convert the feeder from a width of 24 mm to 32 mm (or vice versa), turn the filler piece at the pickup
window to the respective position.
To process 24 mm tapes, you need to use the tape clip as a guidance help. When processing 32 mm
tapes you do not need the tape clip, which can be stored at the park position.
Loosen the two screws fastening the filler piece to the feeder.
Turn the filler piece by 180 degrees.
Fix the filler piece into place with the two screws.
Loosen the screw on the tape clip.
Fasten the tape clip in the required position with the same screw.
NOTICE
This description applies only to 24/32 mm S feeders.
Legend:
A Structure for 24 mm tapes 1 Filler piece
B Structure for 32 mm tapes 2 Tape clip
NOTICE
The filler piece must always be fitted at both tape setups, as the protruding "nose" of the clip
keeps the removal edge pressed down.
Tape Feeder Modules
Inserting the Tape Details for 24/32, 44, 56, 72 and 88 mm S or S DP
User Manual SIPLACE S-Feeder 49
2.4.2 Inserting the Tape
Only for tapes with foil overhang at the beginning of the tape:
Wrap the foil overhang (for threading in) around the beginning of the tape material, tension the foil
along the underside of the tape and hold in place.
(1) Thread the tape from behind into the feeder track.
(2) Open the pickup window:
To do this, press the pickup window down slightly and the turn the latch by 90°, until this engages
audibly.
Now push the tape under the pickup window.
Only for tapes with no overhang at the beginning of the tape:
Free up approx. 2-3 cm of the foil and fold the foil back.
(3) Lift the pickup window and pull the cover tape backwards, over the removal edge.
Now press the removal edge down.
(4) Make sure that the tape perforations are in the transport wheel before you close the removal edge.
NOTICE
Before inserting a new tape, check that the step size is set correctly.
Before you insert the tape, remove any loose components from the feeder. Pay particular
attention to the areas below the removal edge and the pickup window.
NOTICE
For 24/32 mm S feeders when processing tapes with a width of 24 mm:
Make sure that the tape is threaded through the tape clip when you feed it in.