00196376-0102_UM S-Feeder_EN - 第58页

Bulkcase Feeders Operating the Bulkcase Feeder Replacing the Empty Murata Cassette 58 User Manual SIPLACE S-Feeder 3.3.4 Replacing the Empty Murata Cassette ► (1) Check the prism (A) , to make sure that there are no comp…

100%1 / 106
Bulkcase Feeders
Inserting the Murata Cassette Operating the Bulkcase Feeder
User Manual SIPLACE S-Feeder 57
3.3.3 Inserting the Murata Cassette
(1) Press the lock together and push upwards. The following diagram (2) shows the lock when open.
(3) Place the closed Murata cassette onto the funnel, with the opening facing downwards, and push
the lock down again.
(4) Open the Murata cassette, by pushing the slide upwards.
(5) Press the button at the back of the feeder 1x. The components will be moved forwards to the pick-
up position.
Bulkcase Feeders
Operating the Bulkcase Feeder Replacing the Empty Murata Cassette
58 User Manual SIPLACE S-Feeder
3.3.4 Replacing the Empty Murata Cassette
(1) Check the prism (A), to make sure that there are no components in the transition area between
the funnel and the Murata cassette.
(2) Press the lock together, push upwards and remove the empty Murata cassette.
Perform the further steps as described in "3.3.3 Inserting the Murata Cassette" [ ➙ 57]:
Place the new, closed Murata cassette onto the funnel, with the opening facing downwards, and push
the lock down again.
Open the Murata cassette, by pushing the slide upwards.
Press the button at the back of the feeder 1x. The components will be moved forwards to the pickup
position.
See also
3.3.3 Inserting the Murata Cassette [ ➙ 57]
NOTICE
Empty Murata cassettes can be replaced without the need for a machine standstill.
Bulkcase Feeders
Replacing the Feeding Rail at Component Changeover Operating the Bulkcase Feeder
User Manual SIPLACE S-Feeder 59
3.3.5 Replacing the Feeding Rail at Component Changeover
If you want to use the bulkcase feeder for components of a different size, you need to replace the feeding
rail fitted with one which is suitable for the new components.
(1) Loosen the front end of the feeding rail by turning the fixture screw 90° in a clockwise direction.
(2) Open the quick-fit closure at the back of the feeding rail.
(3) Lift the feeding rail off the body.
(4) Tilt the feeding rail towards the back, so that the remaining components slide towards the Murata
cassette.
(5) Turn and shake the feeding rail until all the remaining components are in the Murata cassette.
(6) Close the Murata cassette, by pushing the slide up.
(7) Open the lock and remove the Murata cassette.
To fit another feeding rail and fasten the Murata cassette, proceed as described in "3.3.2 Placing the
Feeding Rails on the Body" [ ➙ 56] and "3.3.3 Inserting the Murata Cassette" [ ➙ 57].
NOTICE
The slide may not be closed while the components are still in the transition area between the
cassette and the funnel.