(4) Shut off main air supply (hand valve). (5) Remove screws holding drive cylinder assy on left and right sides. (6) Raise bank lifter to remove (on replacement side). (7) Remove the 4 screws holding bank up cylinder an…

100%1 / 257
Left PA500750200
Right PA500750100
Bank up detec Bank up
cylinder tor cable
Bank up detector cable
Bank up cylinder mounting
screw
E2756721000
Lifter cylinder shaft
Drive cylinder ass
y
mounting screw
Bank lifte
r
Only attach bank up detector cable on the left.
Lengths differ:
Front is E95577250AO
Rear is E95577250AO
Fig. 9-5-2
1-96
(4) Shut off main air supply (hand valve).
(5) Remove screws holding drive cylinder assy on left and right sides.
(6) Raise bank lifter to remove (on replacement side).
(7) Remove the 4 screws holding bank up cylinder and remove cylinder.
(8) Switch connection of speed controller & bank up detector cable (left only) to the new cylinder.
Provisionally connect cable 10mm from top.
(9) Mount cylinder and insert bank lifter from above.
(10) Screw lifter cylinder shaft into cylinder rod.
(11) Open main air supply.
(12) Adjust speed control for left / right cylinders. (Refer to section9 - 6.)
(13) Mount drive cylinder assy.
1-97
(14) Install one-shot replacement base in main body.
(15) Lowering the bank up detection sensor, fasten it in the gap between where the LED light goes on
and off.
LED light off
Fasten here
LED light on
Fig. 9-5-3