KE-750_MS - 第111页

Chapter 10 Air Apparatus 1. Air Source Identification Cable Assy Replacement (1) Unplug connector. (2) Remove Allen head screw. (3) Remove air source identification cable assy. (4) Reassemble in reverse sequence. Caution…

100%1 / 257
10. Lock Up Valve Replacement
(1) Remove accessory nut.
(2) Slide lock up valve down from main body and remove.
(3) Reassemble in reverse sequence.
PJ301065201
Half union
PJ305065201
Service union
A
ccessory nut
E1619725000
Feeder PWB bracket
1-103
Chapter 10 Air Apparatus
1. Air Source Identification Cable Assy Replacement
(1) Unplug connector.
(2) Remove Allen head screw.
(3) Remove air source identification cable assy.
(4) Reassemble in reverse sequence.
Caution
Shut hand valve before beginning.
Refer to relevant Users' Manual for method of adjusting pressure switch.
A
llen head scre
w
E94037250A0
A
ir source identification cable
assy (Pressure switch)
Connecto
r
Hand valve
Fig. 10-1-1
1-104
2. Filter Element Replacement
(1) Shut off hand valve.
(2) While pulling slide piece down, turn either left or right 45 in relation to main body and pull out.
(3) Remove air filter by rotating filter retainer and remove filter element B. Remove mist separator from
filter element A in the same manner.
(4) Reassemble in reverse sequence.
Mist separato
r
A
ir filte
r
PF901003000
Filter element B
Filter retaine
r
PF901002000
Filter element A
PF901002000
Filter element A
Main bod
y
Slide piece
Hand valve
Fig. 10-2-2
Fig. 10-2-2
1-105