KE-750_MS - 第185页

When changing boards by type, the uni ts above only change Y coordinates. When set values are changed and "Exit" selected, message box will display the changes in fixing position of the unit. Select "OK&qu…

100%1 / 257
4.3 Conveyor Specifications
Select "1/Initial set-up" then "3/Conveyor Specifications" and the conveyor spec setting dialog will
appear as follows.
(1) Setting Headings
No. Item Contents
1 Conveyor Type Conveyors by type
2 Conveyor Reference Surface Reference surface for the machine
3 Conveyor Direction Conveyor direction in reference to the machine
4 Board Type Boards by type
5 Max. Board Size Max. usable board size (Std. board size is X = 410mm, Y = 360mm)
(2) Method of Setting
Enter values for the items in (1) with the tuner button or directly with keyboard.
"L Board" must be selected when setting max. board size. Selecting "Std Board" is meaningless.
When changing conveyor reference surface or conveyor direction, the following MS parameters
and machine setup coordinates must be set at default.
Default Position Modified Data Conveyor Reference
Surface
Conveyor Direction Board Type
MS Parameter CAL Block Position
{
x { (Y only)
VCS Position
{
x { (Y only)
Coplanarity Position
{
x { (Y only)
ATC Position
{
x { (Y only)
CVS Position
{
x { (Y only)
Pick Point Position x x { (Y only)
Machine Setup Reference Pin Position
{ {
x
Secondary Pin Position
{ {
x
Std Edge Position
{ {
x
Parts Waste Position
{
x x
{ Default required
x Default not required
2-17
When changing boards by type, the units above only change Y coordinates.
When set values are changed and "Exit" selected, message box will display the changes in fixing
position of the unit.
Select "OK" to verify changes made to the unit.
Fixing parameters for units with changes must be reset.
Select "Cancel" to return to setting dialog.
Limitation: Conveyors will not move for KE-750 / KE-760 with specifications set for a single motor.
2-18
4.4 Options
4.4.1 Options
Select "1/Initial set-up" then "4/Options" and the option setting dialog will appear as follows.
(KE-730) or (KE-740)
2-19