2. Blow Switch Solenoid Replacement
As the vacuum switching solenoid continuously supplies the main body from the pressure source,
replace after main body pressure has fallen.
Since the blow solenoids are the connector type they are the same for left, right & center. Be careful not
to connect incorrectly. After replacement operate manually to check head blow ON/OFF connections.
SEMS scre
w
SL4034091SC (750)
SL4033091SC (760)
A
ir mount plate
E2501725000
Elbow union
PJ304040511
Support solenoid
PY140507000
Only fo
r
model 750
Plug
PJ020500002
Elbow union
PJ304040511
Plug
PJ020500002
Flangeli
t
NM3034000SF
Fig. 3-2-1
1-38


3. Ejector Replacement
SEMS screw
SL4031691SC
SEMS scre
w
SL4030681SC
Ejector bracket
E2508725000
Ejecto
r
E3066700000
Fig. 3-3-1
- ATC Nozzle Setup
- Vacum value without Nozzle
1-39