Affixing HMS seal Cut along dotted line as shown in diagram. Clean affixing surface with alcohol to remove grease and affix in position shown in diagram. (Align seal arrow with laser projector.) Fig. 3-7-2 Laser projecto…

100%1 / 257
7. HMS Replacement (Optional)
HMS is adjusted with the sensor and amp. Sensor and amp are always replaced simultaneously (It is not
possible to change only one.)
7.1 HMS sensor replacement
Laser senso
r
SEMS cap screw x 2
SL6042592TN
SEMS cap screw x 2
SL6030692TN
(SEMS cap screw x 2)
SL6030892TN
Fastened with cable tie
Model 750: HMS holder (750)
E3651725000
Model 760: HMS holder (760)
E3652725000
Camera bracket D
E3809725000
Fig. 3-7-1
1-45
Affixing HMS seal
Cut along dotted line as shown in diagram.
Clean affixing surface with alcohol to remove grease and affix in position shown in diagram. (Align seal
arrow with laser projector.)
Fig. 3-7-2
Laser projecto
r
Fig. 3-7-3
1-46
7-2 HMS amp replacement
Head tap plate
E2502725000
Height sensor cable ass
y
E95757210A0
SEMS cap scre
w
SL4041081SC
Fig. 3-7-4