Coplanarity module 2 Retrofit instructions Coplanarity module - SIPLACE HF series 10/2004 Edition 23 : Screw the cop lanarity m odule o nto the mou nt (3 M4 x 8 screws c ounter su nk). 2 : Screw on th e mount for th e co…

100%1 / 34
2 Retrofit instructions Coplanarity module - SIPLACE HF series Coplanarity module
10/2004 Edition
22
2.4 Preparatory work
: Switch the placement machine off at the main switch.
: Dock out the component tables on the relevant side of the machine.
: Remove the side wall cover on location 4.
: Remove the computer unit.
2.5 Retrofit
: Remove the reject bin from the relevant side of the machine.
: On older machines:
Remove the mount for the reject bin together with the sensor (M5 hexagon, size 1 slotted).
2
Note the installation position of the sensor. 2
2
2
2
2
2
2
Mount for
reject bin
Sensor
Coplanarity module 2 Retrofit instructions Coplanarity module - SIPLACE HF series
10/2004 Edition
23
: Screw the coplanarity module onto the mount (3 M4 x 8 screws counter sunk).
2
: Screw on the mount for the coplanarity module (2 x M6x12):
Top screw + bottom screw (in top holes in the base).
2
2
: Open the door of the extension kit without servo unit on the output belt side.
: Pull the connecting cable for the coplanarity module through the machine base using the
threading aid.
2
2
2
2
2
2
2
2
2
2
2
2
Screws
2 Retrofit instructions Coplanarity module - SIPLACE HF series Coplanarity module
10/2004 Edition
24
: Disconnect the cable at X22ra.
: Connect the new cable (03021751-01) at X22ra2 and X22ra.
2
Fig. 2.10 - 1 SUB Distributor
2
2
2
2
2
2
2
2
Connect at these
plugs
Cable with 2 plugs