00194335-02 - 第28页
2 Retrofit instructions Coplanarity module - SIPLACE HF ser ies Coplanarity module 10/2004 Edition 28 2.2 Activate coplanarity in the SITEST program : S t art t he SI TEST prog ram. : In the main view , s elect "Opt…

Coplanarity module 2 Retrofit instructions Coplanarity module - SIPLACE HF series
10/2004 Edition
27
: Plug the cable to the coplanarity module in at the RS 485 interface on the front panel of the
computer unit.
2
: Push all the units back into position and refit all the covers.
: Connect the RS232 interface of the coplanarity module and the COM-A interface of the ma-
chine controller using the interface cable (00336796-02).
: Stick the warning label visible onto the coplanarity module.
2
: Switch the placement machine on at the main switch.
Cable to coplanarity module

2 Retrofit instructions Coplanarity module - SIPLACE HF series Coplanarity module
10/2004 Edition
28
2.2 Activate coplanarity in the SITEST program
: Start the SITEST program.
: In the main view, select
"Options --> Operator level --> Service engineer --> Activate".
: Select
"Options --> Machine configuration --> (relevant) Handling area".
: Activate
"ILD 2000 (type 17)" and "Accept".
2
: Shut down the station computer and switch off the placement machine at the main switch.
2.3 Check the safety shutdown
The safety measurement checks whether the voltage (24 V) is switched off when the safety circuit
is broken (e.g. protective covers opened or emergency stop pressed). 2
: Unplug the coplanarity sensor cable from the RS485 slot (see photograph).
: Plug in the coplanarity test plug at this slot.
2
2
RS 485

Coplanarity module 2 Retrofit instructions Coplanarity module - SIPLACE HF series
10/2004 Edition
29
: Close all the safety devices.
: Switch the placement machine on at the main switch.
None of the four LEDs on the test plug must light up.
2
Activation of the LEDs on the coplanarity module (computer unit) is not the same as activation of
the LEDs on the test plug. The activation and deactivation of LEDs must therefore always be
checked at the test plug.
The coplanarity sensor switches off again 20 minutes after it was last activated. You should there-
fore carry out the checks within this period. 2
2
The following calibration sequence (which is carried out using the SITEST program) is only used
here to switch on the sensor, i.e. it must not be saved. 2
2
2
: Switch the control "ON“ (Start button):
The machine carries out a reference run.
All 4 LEDs on the test plug must light up.
: Start SITEST and select:
"Twin -> Coplan -> Calibrate Coplan".
: Now open and close all four protective covers one after another and check the activation of the
LEDs on the test plug:
When you open a protective cover -> none of the 4 LEDs must light up.
When you close one or all of the protective covers and press the "ON“ button -> all 4 LEDs
must light up.
: Press and release all three 3 emergency stop buttons one after another and check the activa-
tion of the LEDs on the test plug:
When you press an emergency stop button -> none of the 4 LEDs must light up.
When you release the emergency stop button and switch the control "ON" -> all 4 LEDs must
light up.
2
2
2
2
2
2
2
2