6 Gantries
6.3 X and Y axis
108 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Fig.136: Casting marks on the incremental encoder
The incremental encoder must be aligned
with a gap of 0.4mm
(golden scale) or
0.75mm
(black-white scale) to the scale.
Use the corresponding thickness gauge
(plastic).
Align the incremental encoder. Pay at-
tention to the following points:
Set the exact height of the scale.
Align the incremental encoder, us-
ing the two casting marks (arrows)
,
which mark the read area.
Align the incremental encoder paral-
lel to the scale. The gap at the top
and bottom must be the same size.
Tighten the fastening screws.
Reconnect to the electricity supply (connector X14 or X15 on head interface).
CAUTION
Check how the cables are run!
Make sure that the axes can be moved without damaging the cables.
Fasten the cables with cable ties.
Move the gantry into the end stopper and check that the buffer does not come into contact
with the cable.
Check the track signals with the test device (see 6.3.4 "Track Signals and Zero
Pulse" [}111]).
6 Gantries
6.3 X and Y axis
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 109
6.3.2 Replacing the Y axis incremental encoder
Parts, equipment and tools
Select the correct incremental encoder:
Machine Incremental encoder (read head)
SIPLACE X4i S, X4 S, X3 S, X2 S MS22/25 Y axis [03094996‑xx] (including plastic
thickness gauge)
SIPLACE X4i S micron, X4 S micron
SIPLACE CA PLP
MS30 Y axis [03102065‑xx]
If needed, mounting bracket for Y axis sensor [03086842-xx]
For MS22/25 incremental encoder: test device PG1-I [03102699‑xx]
For MS20/30/35 incremental encoder: test device PG-U [03071361‑xx] from FS02 (see also
technical information "Checking the track signals at the X and Y axes" [DE:TI2019‑02D04]
[EN:TI2019‑02E04])
Ethanol
Isopropanol – IPA can be used as an alternative.
Overview
Fig.137: Overview of incremental encoder
1. Fastening screws (3x) for holder
2. Holder
3. Incremental encoder
4. Screws (2x) fastening the incremental
encoder
Fig.138: Overview of gantry interface
1. Gantry interface
2. Trailing cable holder on gantry
6 Gantries
6.3 X and Y axis
110 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation.
1.2 "Preparatory work..." [}16]
Unplug the incremental encoder cable from the gantry interface. In this case make a note of
the position to make clear assignment easier later on.
Unthread the connection cable as far as the incremental encoder.
Remove the three screws fastening the bracket and then carefully remove this together with
the incremental encoder on it.
Remove the two screws fastening the incremental encoder and then carefully remove this
from the bracket.
Installation
Clean the reading surface of the incremental encoder with a cloth and ethanol or with a Q tip.
Use the two screws to fasten the incremental encoder to the bracket.
Use the three screws to install the bracket. To do this, place the thickness gauge provided
between the incremental encoder and the scale, so that there is a gap. This gap must either
be 0.4mm
(golden scale) or 0.75mm (black-white scale). Use the corresponding thickness
gauge.
Reconnect to the electricity supply.
CAUTION
Make sure that the cables do not rub against anything.
Make sure that the axes can be moved without damaging the cables.
Fasten them with cable ties
Check the track signals with the test device (see 6.3.4 "Track Signals and Zero
Pulse" [}111]).
6.3.3 Mechanical adjustment of the incremental encoder
The incremental encoders (read units) on the X and Y axis are adjusted exactly to the position of
the incremental scale. The two limit marks on the incremental encoder show where the top/bottom
positions of the scale should be.
Set the incremental encoder mechanically to a distance of 0.75 mm to the incremental encoder.
NOTICE
Plastic disks
To set this distance, use one or more small plastic disks with a total thickness of 0.75mm.
Feeler gauge 0.75mm plastic [03090774-xx]
After this adjustment of the incremental encoder you have to check the zero pulse and track sig-
nals.
Correct installation should ensure correct count and zero pulse signals. For troubleshooting pur-
poses (error analysis and fixing), you will need to measures these signals.
Please also observe section 6.3.4 "Track Signals and Zero Pulse" [}111].