6 Gantries 6.6 MHCU, boards and camera Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 149 Version 05 Fig.192: X base adapter C&P LED [03045647-05] LED Color Status Signal name Description H1 GN ON CO_SENSOR …

6 Gantries
6.6 MHCU, boards and camera
148 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
6.6.2 X base adapter C&P
This board is used for the SIPLACE C&P20x and CPP.
NOTICE
SIPLACE C&P20 P
The X base adapter needs at least function level 08 for the SIPLACE C&P20 P head. In this
case, you may need longer flat ribbon cables.
Version 09
Fig.191: X base adapter C&P [03045647‑xx]
Connections [03045647-09]
1, 2 X1-X2 Flat ribbon connection for CPP
or C&P20
3 X3 Connection to the head interface
board C700
4, 14, 15 X4, X14, X15 Connector for MHCU
(together with X14, X15)
5 X5 Test connector for FPGA
6 X6 Programming connector for FPGA 7 X7 Test connector MHCU
8 X8 Connectors for inlet vacuum
sensor (cable X1a)
H LED H3- H9
S1 Switch S1 intermediate circuit voltage
Z axis
40V C&P20 (switch top)
150V CPP(switch bottom)

6 Gantries
6.6 MHCU, boards and camera
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 149
Version 05
Fig.192: X base adapter C&P
LED [03045647-05]
LED Color Status Signal name Description
H1 GN ON CO_SENSOR CO sensor active
H2 GN ON - The programming plug for the MHCU is
connected
H3 RD ON FPGA_TEST_6 1.5V power supply error
H4 RD ON FPGA_TEST_2 3.3V power supply error
H5 RD ON FPGA_TEST_4 5V power supply error
H6 RD ON FPGA_TEST_1 15V power supply error
H7 RD ON FPGA_TEST_3 DP power supply error, temp. without
function
H8 RD ON FPGA_TEST_5 24V power supply error
H9 RD ON POWERFAIL_LOCAL PowerFail on circuit board
The voltage monitors trigger as soon as the target voltage is exceeded or undershot by 5%.
Switch S1 [03045647-05]
Switch Status Function
S1 40V Intermediate circuit voltage for Z axis --> C&P20A/M/P
150V Intermediate circuit voltage for Z axis --> CPP
Switch S1 sets the intermediate circuit voltage for the Z axis
If the setting is incorrect, no damage will be done. However, an MHCU error message will be is-
sued.

6 Gantries
6.6 MHCU, boards and camera
150 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
6.6.3 X Base adapter Twin
Fig.193: X base adapter Twin [03062201-03]
X4 X14 X15 Connection for MHCU (Twin mod-
ule2)
X9 X16 X17 Connection for MHCU (Twin mod-
ule1)
X30 X31 Connections for Twin module 2 X32 X33 Connections for Twin module 1
X3 Connection on the head interface H2 to H9 LEDs (see below)
LED [03054879-03]
LED Color Status Signal name Description
H2 GN ON - HMCU2 programming connector connected
H3 RD ON FPGA_TEST_6 1.5VDC PowerFail
H4 RD ON FPGA_TEST_2 3.3VDC PowerFail
H5 RD ON FPGA_TEST_4 5VDC PowerFail
H6 RD ON FPGA_TEST_1 15VDC PowerFail
H7 RD ON FPGA_TEST_3 DP PowerFail, not used
H8 RD ON FPGA_TEST_5 24VDC PowerFail
H9 RD ON POWER-
FAIL_LOCAL
PowerFail board:
ON, when 1.5VDC, 3.3VDC, 5VDC and 15VDC are
outside the permissible tolerance
The voltage monitors trigger as soon as the target voltage is undershot by 5%.