00198829-01_SM_X-Series-S_Hxxxx_EN - 第254页
8 Head exchange 8.1 Fast Hardware Exchange 254 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 Fig.338: Service menu ► Select the Service button. ► Select the Fast hardware exchange button. Fig.339: Fast Hardwar…

8 Head exchange
8.1 Fast Hardware Exchange
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 253
8 Head exchange
DANGER
Observe User Manual
► Please observe the safety instructions in the user manual for all work!
See also
2 8.2 "Differentiation of the SIPLACE C&P20 head variants" [}257]
8.1 Fast Hardware Exchange
Fast Hardware Exchange (FHE) enables you to change a placement head within 15minutes.
NOTICE
Only SIPLACE CPPx and SIPLACE C&P20x
FHE is only possible with SIPLACE CPPx and SIPLACE C&P20x.
SIPLACE Twin needs to be manually processed and calibrated.
Equipment and tools
The head exchange kits contain all the tools required for replacing the relevant head:
●
Head Exchange Kit option for SIPLACE CPx [03109694‑xx]
●
Head Exchange Kit option for SIPLACE CPP [03109570‑xx]
●
Head Exchange Kit option for SIPLACE C&P20P [03114808‑xx]
●
Head Exchange Kit option for SIPLACE C&P20P2 [03172724‑xx]
8.1.1 Preparing the FHE in the Software
Fig.337: Select operator level
► Select the button.
► Select the button.
► Switch over to the operator level Ma-
chine service.
ð The button will be shown.

8 Head exchange
8.1 Fast Hardware Exchange
254 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Fig.338: Service menu
► Select the Service button.
► Select the Fast hardware exchange
button.
Fig.339: Fast Hardware Exchange – select head
► Highlight the heads to be replaced.
► Select the Prepare for exchange and
shutdown button.
The following actions will be carried out
automatically:
●
The current nozzles will be returned
and calibration nozzles will be picked
up, if present.
●
A nozzle and height reference run will
be carried out.
●
The machine will be shut down.
In a next step you can dismantle the heads.

8 Head exchange
8.1 Fast Hardware Exchange
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 255
8.1.2 Removing and Installing the Placement Head
► For actually removing and installing the placement head hardware, proceed as described in
the relevant chapter.
8.6 "Replacing the SIPLACE C&P20P2" [}265]
8.5 "Replacing the SIPLACE C&P20P/M2" [}260]
8.7 "Replacing the SIPLACE CPP/M" [}270]
8.1.3 Completing the FHE in the Software
► Switch the machine on.
After being switched on again the machine issues the message Changed heads detected and ex-
pects a calibration.
Fig.340: Select operator level
► Select the button.
► Select the button.
► Switch over to the operator level Ma-
chine service.
ð The button will be shown.
Fig.341: Service menu
► Select the Service button.
► Select the Fast hardware exchange
button.