00198829-01_SM_X-Series-S_Hxxxx_EN - 第350页

9 Component feeding 9.4 Docking Station for Component Trolley 350 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 9.4.9 Replacing the Complete Coupling - Earthing and Compressed Air for the Bulk Case Parts You can…

100%1 / 382
9 Component feeding
9.4 Docking Station for Component Trolley
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 349
Fig.495: FCU cover plate
Remove the two screws(2) fastening
the FCU cover plate(1)
.
Fig.496: Connections
Unplug all electrical connections from
the terminal strip of the FCU.
Fig.497: Fastening screws
Remove the screws(1) fastening the
FCU on both sides.
Depending on the version, there will be
four or six screws.
Carefully lever the FCU out of the locating pins.
Remove the earth terminal.
Installation
Set the DIP switches on the FCU.
Refit the cover plate and the FCU.
Place the connection cable in the recess and carefully push in the new FCU. Make sure you
do not pinch any cables.
Pull the ends of the cables out from under the terminal strip.
Plug in all electrical connections as labeled on the terminal strip.
Further installation is performed by following the above instructions in the reverse order.
9 Component feeding
9.4 Docking Station for Component Trolley
350 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
9.4.9 Replacing the Complete Coupling - Earthing and Compressed Air for the
Bulk Case
Parts
You can either replace the individual coupling socket or the complete coupling unit for ground and
compressed air.
03017026-xx Coupling socket for compressed air coupling
03017025-xx Complete coupling for ground connection and compressed air
Equipment and tools
00353832-xx Allen key set
Overview
3
1
2
Fig.498: Coupling on docking station
1. Coupling socket for component trolley
compressed air coupling (bulkcase
feeder)
2. Compressed air connection to the
pneumatic control value 5.5 bar
3. Component trolley ground coupling
(bulkcase feeder)
Removal/installation
3
2
4
1
Fig.499: Removing the coupling
1. Fastening the complete coupling
(ground and compressed air)
2. Coupling socket for compressed air
coupling
3. Mount
4. Pneumatic connection to pressure con-
trol valve 5.5 bar at the back
 CAUTION!
Risk of injury from compressed air
Risk of injury when disconnecting
pressurized compressed air lines.
Switch off the compressed air supply.
.
Individual replacement of coupling socket for compressed air coupling
Unplug the compressed air connection.
Use an open-end wrench to unscrew the coupling socket from its mount.
Screw in the new coupling socket and connect the compressed air supply.
Switch on the compressed air supply.
Check the set pressure of 5.5 bar at the pressure control valve (located at the back).
9 Component feeding
9.4 Docking Station for Component Trolley
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 351
Replacing the complete coupling for ground and compressed air
Unplug the compressed air connection.
Remove the fastening screw and remove the complete unit.
Fit the new assembly and reconnect the compressed air supply.
Switch on the compressed air supply.
Check the set pressure of 5.5 bar at the pressure control valve (located at the back).
9.4.10 Replacing the unlocking pushbutton
Parts
Fig.500: Pushbutton
00334095-xx Unlocking pushbutton
Equipment and tools
00353832-xx Allen key set
Wire cutters
Cable tie
Overview
1
Fig.501: Unlocking pushbutton on docking station
1. Unlocking pushbutton