00198829-01_SM_X-Series-S_Hxxxx_EN - 第53页
3 Power supply 3.4 Power supply and transformer modules Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 53 Fig.52: LED status Monitoring the voltage absence after switch-off The voltage at the measurement points …

3 Power supply
3.4 Power supply and transformer modules
52 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Measurement with known reference voltage
To conclude the self-test, check the voltage tester with a known reference voltage.
Fig.50: Test with reference voltage
You can use the service socket (if present)
on the power supply (disabled with "110V
option") or any other electrical socket.
Measure the voltage present between the
pins and at PE (ground).
Measuring the voltage absence directly after switching machine off
Fig.51: Check voltages
When the machine has been switched off,
the full voltage is still present at the meas-
urement points X303 and X304.
Measurement is always performed at the ref-
erence point (GND)!
●
X303 – X305 GND: 300+/‑10V OUT
●
X304 –X305 GND: 300+/‑10V
Test 300V IN_X303-X305:
Voltage currently present
Test 300V OUT_X304-X305:
LED display Output 1 at AC/DC converter
Green: Voltage over 220V
The power pack shows an LED display for output 1 > 220 V in green, which means that the voltage
is still over 220 V!
DANGER
Dangerous voltages
The power supply contains energy-storing components (CAP and capacitors on the FDB
assembly)!
After switching off at the main switch or disconnecting from the main supply, hazardous
voltages are still present at some points of the assembly interior for a period of approx. five
minutes.
► Always observe the maintenance intervals!
The following figure explains the LED status of power packs PS1 and PS2 (300VDC):

3 Power supply
3.4 Power supply and transformer modules
Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021 53
Fig.52: LED status
Monitoring the voltage absence after switch-off
The voltage at the measurement points only discharges slowly.
After switch-off, the voltage drops from 300VDC to under 5VDC in approx. five minutes.
It is only then possible to pull the SMPS out of the machine without hazard and work on it.
Fig.53: Checking voltages (X-Series S from Hxxxx)
Fig.54: Measurement values
As soon as the voltage has undershot a value of 220VDC, the LED display on the power pack
changes!
DANGER
Measurement values below 5VDC
Measure between the following points:
► X303 (IN) – X305 (GND) < 5VDC
► X304 (OUT) – X305 (GND) < 5VDC

3 Power supply
3.4 Power supply and transformer modules
54 Service Manual SIPLACE X-Series S (from Hxxxx) 01/2021
Fig.55: LED on the buffer module(CAP)
► Check the LED on the buffer module
(CAP).
DANGER!
Once the LED on the buffer module
(CAP) does not light any longer, it is
possible to work on the power supply
without hazard!
.
3.4.4 Replacing the buffer module
Parts, equipment and tools
●
Buffer module PCS417.771 [03106016-xx]
Overview
Fig.56: Buffer module
1. Buffer module